Patchmark70‹ All plug-ins
Manual contents
Sounds and registers

Local library, files and backups

Local library is everything Patchmark70 keeps on this Mac: the sounds you save and the backups of your registers. It lives in ~/Library/Patchmark70, as standard PCM70 .syx files, and every project and window on this Mac sees it. The commands are in the ☰ menu's Local library section, and the sounds in the patch list's Local library tab.

Save to local library

☰ › Save to local library adds the window's whole sound to local library, named after the sound. It never touches the PCM70. The Modified dialog offers it too, as does the message for a sound sent from the PCM70's front panel.

To use a saved sound, open the patch list's Local library and click Open: it opens in the window and, with the PCM70 connected, is sent to it whole.

Import or restore .syx

☰ › Import or restore .syx… first lists your backups and the .syx files in ~/Library/Patchmark70, newest first, each with its date and what it holds. Open (or a double-click) opens one; Other file… picks a .syx anywhere else, such as a bank from another PCM70 owner or an old librarian; Show in Finder shows the selected file.

Then it lists the file's PCM70 sounds, ignoring anything for other devices, and Destination says where they go:

  • Local library, the default: Import adds the sounds switched on to local library. Nothing is sent to the PCM70; Store puts a sound on the unit.
  • The unit's registers, named after it, such as PCM70-1 registers, for a backup or bank: Restore puts each sound switched on back into its own register, as described below. Registers switched off are left as they are.

Empty registers start switched off and shaded. ‹ Files goes back to the list.

It waits until a firmware is chosen in Device setup. A sound that uses Inverse Room on a 2.x unit is imported but never sent; a MIDI Clock route on 2.x is flagged. A value outside the PCM70's range is marked, and hovering the sound names the controls out of range: it is imported but not sent until you bring it into range, and it can't go back into a register, so it is switched off when the destination is the registers.

A restore runs like this:

  1. It reads all 50 registers from the PCM70 first, fresh, and saves them as a backup in local library. If a register doesn't answer, nothing is stored and it says so.
  2. It shows what will change, worked out from that read, for example "36 registers change". While this shows, nothing reaches the PCM70, automation included, and a banner says "Automation and edits wait until you confirm or cancel the restore".
  3. Store 36 registers stores only the registers that differ, one at a time, each checked by reading it back: "Storing and checking R1.4 · 15 of 36". Cancel stops there: registers already stored stay stored.
  4. It ends with what was done, for example "Stored and checked 34 registers.", "Not stored: R1.5, R1.6." and where their earlier sounds are saved in local library.

On 2.x, a sound in the bank that uses Inverse Room is skipped and named.

While a backup or a restore runs, the other actions that talk to the PCM70 wait, and say so.

Export .syx

☰ › Export .syx… writes sounds to a .syx file, exactly as they are. Choose What: Current sound, the sound in the window with your edits, or All registers (as last read); and the MIDI Channel the file is for.

To export patches from the list, select them (⌘-click adds one, ⇧-click a run), right-click one of them and choose Export .syx…: it writes every patch selected, as Selected patches.

Back up all registers

☰ › Back up all registers… reads the PCM70's 50 registers into a dated bank in local library › Backups, with progress and Cancel. Once read, it asks you to name the backup: its dated name is offered, so type another and press Save, or press Esc to keep the dated one. Then it says where the bank is, with Show in Finder. Do it before you change anything on the unit you'd want back. To put a backup back, open it from Import or restore .syx and choose the registers as its destination.

This manual is for version 0.9.0.