Manual contents
PCM70 setup guide
Patchmark70 talks to the PCM70 over MIDI, both ways: it sends sounds and edits to the unit, and reads back what the unit answers. A few settings on the PCM70's front panel decide whether that works. Set them once and Patchmark70 can read, edit and store your sounds.
You'll find this guide from the plug-in at ☰ › Help › Manual.
What changes with the firmware
Choose your unit's firmware in Device setup's Firmware row (see Getting started). This is what it changes:
| 2.x | 3.0x | |
|---|---|---|
| Inverse Room | Never sent | Yes |
| MIDI Clock routes | No | Yes |
| Velocity routes | Yes | Yes |
| Presets | P0.0–P6.6 | P0.0–P6.5 |
Inverse Room can crash a 2.x unit, so Patchmark70 never sends a sound that uses it to a unit set to 2.x. Note Velocity and Performance Control (the Soft Knob) have been confirmed on a 2.x unit and are offered as on 3.0x. Firmware 1.x isn't supported.
Cabling
MIDI OUT to the PCM70's MIDI IN, and its MIDI OUT back. Don't use THRU.
Connect your MIDI interface's MIDI OUT to the PCM70's MIDI IN, and the PCM70's MIDI OUT to your interface's MIDI IN. Patchmark70 needs the second cable to hear the unit's answers. A cable from the PCM70's MIDI THRU only repeats what the unit receives, so Patchmark70 would never hear the unit itself.
A modulation route's source, such as a keyboard's mod wheel, has to reach the PCM70's MIDI IN. With this cabling, plug the keyboard into the Mac and tick it in Settings › Controllers: Patchmark70 passes on what the sound's routes use (Modulation routes from your keyboard).
The settings
The tables for your firmware, below, give each setting's value.
| Setting | Why |
|---|---|
| MIDI channel | The PCM70 answers only on its own channel, the one you chose in Device setup |
| Omni | With Omni on, the unit also takes messages meant for other channels |
| Program Change | So a program change recalls the memory Patchmark70 asks for |
| Memory Protect | So Store can write to your memories |
With 3.00 / 3.01
All four settings are in the control program. Load 7.0 CONTROL PGM and enter parameter mode to reach its settings:
| Setting | Value |
|---|---|
| 7.0 CONTROL PGM › 1.0 MIDI CHNL | The channel you chose in Device setup |
| 1.1 OMNI MODE | Off |
| 1.2 PGM CHANGE | FIX |
| 0.1 M PROTECT | Off while storing |
| 1.3 RESET MIDI | Resets MIDI controller values |
1.2 PGM CHANGE has three values, OFF, FIX and TABLE: choose FIX. 1.0 MIDI CHNL is the channel the unit listens on and answers on. 1.3 RESET MIDI isn't a setting: it puts the unit's MIDI controller values back to their defaults.
If PGM CHANGE isn't FIX, a recall can load another register than the one asked for. Patchmark70 notices and says which it loaded, and asks you to set PGM CHANGE to FIX.
With 2.x
A 2.x unit has the same control program, at the same places. Load 7.0 CONTROL PGM and enter parameter mode to reach its settings. The last column gives the pages of the PCM70 Owner's Manual for software 2.00 that describe each one:
| Setting | Value | Owner's Manual pages |
|---|---|---|
| 7.0 CONTROL PGM › 1.0 MIDI CHNL | The channel you chose in Device setup | 4-2, 5-7 |
| 1.1 OMNI MODE | Off | 4-2, 5-7 |
| 1.2 PGM CHANGE | FIX | 3-7, 4-2, 5-7 |
| 0.1 M PROTECT | Off while storing | 2-8, 4-2 |
| 1.3 RESET MIDI | Resets MIDI controller values | 3-7, 4-2 |
The 2.00 manual's table of the control program (page 4-2) spells 1.2 as PGM CHNG. It has three values, OFF, FIX and TABLE: choose FIX. 1.3 RESET MIDI isn't a setting: it puts the unit's MIDI controller values back to their defaults.
Memory Protect
Memory Protect stops stores to used memories, not unused ones. A failed store can have other causes too.
With Memory Protect on, the PCM70 won't overwrite a memory that already holds a sound. It still lets you write to an unused memory, so a store to an empty memory can work while one to a used memory doesn't.
After a store, Patchmark70 reads the memory back to check it. If the memory still holds the old sound, it says "Not stored" and points to this guide. Memory Protect is the likely cause, but not the only one: a loose MIDI cable, the wrong channel, Omni or another program on your computer talking to the PCM70 at the same time can stop a store too.
The PCM70's display after an edit
Each change Patchmark70 makes on its own takes the PCM70 into parameter mode, on the parameter it changed: the display shows that parameter, and a route's patch flashes. That's how the PCM70 takes edits over MIDI, and the sound is as you set it. In parameter mode the PCM70's number keys pick parameters, not programs, and it ignores program changes, so before a recall Patchmark70 sends the PCM70 its own sound first, which takes it back to program mode (the display shows 5.0). To pick a program on the front panel, press PGM first. LOAD only steps through a patch's fields.
Other software
Other software, such as another editor or a DAW's own SysEx, can still send to the PCM70 while Patchmark70 does. Patchmark70 can't see it, so close it while you edit or store. Two Patchmark70s are another matter: see Sharing one PCM70.
This manual is for version 0.9.0.