Manual contents
The patch list
The patch list shows your PCM70's registers and factory presets, and the sounds saved on this Mac, and recalls them.
Opening the patch list
Double-click the register number or the sound's name in the patch block. Once a sound is loaded, the list covers the whole window; ← Back to Sound at its top, or Esc, closes it. With no sound loaded yet, it opens under the header and stays there.
Each row shows the patch's number, as the PCM70 numbers it, its name, its algorithm, a star and a Recall button. The patch in the window has its row tinted, its name in colour and its Recall filled.
Registers, Presets and Local library
- Registers: the PCM70's 50 user registers, R0.0 to R4.9, with the names and algorithms from the last read. An unused register reads "Unused", even if an old name is left inside it. A register not read yet shows just its number and a dimmed dash.
- Presets: the PCM70's factory presets for the firmware chosen: P0.0 to P6.6 on 2.x, 43 presets; the 3.00 / 3.01 list has Inverse Room in its row 6. Their names and algorithms are known before any read. Patchmark70 never ships their sounds: a recall loads the preset on your own PCM70 and reads it in.
- Local library: the sounds saved on this Mac (Local library, files and backups).
With Use banks off in Device setup, the three show as one list instead of tabs. Hide empty leaves out the unused registers.
Recalling a patch
Click Recall on a register or a preset: Patchmark70 sends the PCM70 a program change and reads the sound into the window, and the list stays open so you can try the next one. The recall is one undo step, "Recall R2.6". Clicking a row only selects it.
Double-click a row, its name or its Recall, or press Return on the selected row, to recall it and go straight to its controls. When Recall is greyed, a double-click does nothing, and the help line says why.
On a local library sound, the button reads Open: it opens the sound in the window and, with the PCM70 connected, sends it whole.
With Send Program Change off in ☰ › Settings…, Recall sends nothing and shows the copy of the register from the last Read all; a register with no copy can't be recalled, and the help line says why.
Renaming a register and reading its name
Right-click or Control-click a row, or press Control-Return on the selected row, for its menu. It opens where you clicked. It lists only what the row can do, and ends with Export .syx…, which writes every row selected to a .syx file (see Local library):
- Rename… opens a name field in the row. So does a slow click on the selected register's name: a click, a pause, a click, as in the Finder. The field takes what the PCM70 can show, A to Z, 0 to 9 and space, up to 13 characters. Return keeps the new name; Escape keeps the old one. Patchmark70 then renames the register on the PCM70 the way Store stores: it reads the register and keeps it in Backups, stores it again under the new name and reads it back. The sound in the window doesn't change.
- Read name from PCM70 reads just that register, so its row shows what the PCM70 holds now, for example after you renamed it on the front panel.
A factory preset's menu has neither, as presets can't be renamed. Both are greyed while the PCM70 can't be reached, or while Read all or a backup runs, and the help line says why.
A sound in local library can be renamed the same way: Rename… or a slow click on its name. The new name goes into the sound and its file on your Mac, and it keeps its star. Its menu has no Read name from PCM70, as the sound is on your Mac, not on the PCM70.
Favourites and search
Click a row's star to mark it a favourite, and the ★ at the top to list only favourites. Favourites belong to the PCM70 in Device setup, so each saved PCM70 has its own.
Search finds patches by name, number or algorithm as you type; Esc clears it.
Read all
Read all, beside Search, reads the 50 registers from the PCM70 one at a time, in a box that shows the register being read, to bring their names and algorithms up to date: the PCM70's own front panel may have changed them since. The line under the list says when they were last read. Cancel, or Esc, stops after the register being read: the ones read keep their new names, the rest what they showed before.
A PCM70 just set up in Device setup is read in full by itself: see The first read.
Keep Mix and Wet Level while browsing
On an aux send you may want the PCM70 to stay fully wet whatever patch you recall. Click the padlock beside Hardware Mix or Wet Level in the common strip to keep it. A recall then works as usual, and Patchmark70 puts the kept value back on the PCM70 right after it, and checks it. A toast says what was kept, for example "Mix kept at 100 % (locked)", and Register reads "Changed from R2.6" with a padlock.
The padlocks are off in a new window and kept with the project. They act on recalls and on opening a saved sound only: never on your own edits, automation, reads, A/B or a project reopening, and they never store into a register.
This manual is for version 0.9.0.