Patchmark‹ All plug-ins
Manual contents
For version 0.9.9 · beta · Change
Devices

Lexicon MX400 Stereo

Question Answer
Does Patchmark work with the MX400 Stereo? Documented, untested
Reads its patch names, from the unit or a backup? No
Backs it up over SysEx? No
Turns its sound controls (MIDI CC and NRPN)? Documented, untested
Edits whole patches over SysEx? No

Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Lexicon MX400 Stereo's patches inside your DAW project (198 numbers in 2 banks, 99 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. It keeps patch names, not sounds: the patches themselves stay on the unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.

The MX400 or MX400XL in its Stereo Configuration. Set the unit's Configuration to match this template: each Configuration has its own programs, and a Program Change loads from the active one. MIDI Program Receive must be on in the System menu (p. 33).

Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.

The Lexicon MX400 Stereo template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.

What Patchmark does with it

  • Recall: 99 patches in each of 2 banks (Factory, User), numbered 001–099. Patchmark sends Bank Select LSB (CC 32), then Program Change, on MIDI channel 1 to start with.
  • Factory names: 99 patches in Factory carry the maker's own names.
  • Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
  • Names on the unit: the unit shows patch names, so renaming a patch here renames it in Patchmark only, and Patchmark says so the first time (Renaming a patch).

Connecting it

  • Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
  • The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
  • Insert the plugin as an audio effect on any track; the audio passes through untouched.

Sound controls

The Patch tab turns 39 of the MX400 Stereo's sound controls, in the Effect 1, Effect 2 and Routing sections, and puts any on a DAW lane (Sound controls).

On the MX400, System ▸ MIDI CC Receive: On. What each knob moves depends on the program's effects and routing: rename the knobs per program.

Values on the Patch tab

Of its 39 controls, 2 show their values as the MX400 Stereo's manual gives them (units, names, %), and 37 show the plain number it takes.

Plain numbers: the CC map names the knobs, types, bypasses, tempo and routing but gives no values for them, and what each knob does changes with the effect.

Sources

  • Lexicon MX400 / MX400XL Owner's Manual PN 18-0446V-F (2018); the XL differs only in its digital connections (p. 53). Each Configuration (Dual Stereo, Stereo, Surround, chosen in the System menu, p. 30) has its own Factory and User banks (p. 8), and a Program Change loads from the active one (p. 33): set the unit to this template's configuration. p. 33 MIDI Channel A (1; Channel B drives Program B in Dual Stereo) and MIDI Program Receive; p. 45 MIDI Implementation Chart, Program Change 0-98 = programs 1-99, CC 32 0 = Factory and 1 = User (the MIDI Implementation Chart). Factory names from 'Stereo Programs', p. 51, as printed: 18 and 19 are both ACOUSTIC PLATE, 31 and 99 both IN REVERSE. Tags: a program with an MX200 program's title takes its tags, the others from the name; a name that names no effect, space or instrument is Ambience. The MIDI chart lists System Exclusive as 'Lexicon Editor Only' and the manual documents no message, so the template has no SysEx: backups and names go through Lexicon's MX-Edit only. Unconfirmed: no unit has been checked.
  • Lexicon MX400 Owner's Manual, MIDI CC Map (PDF pp. 55-56) Values: the effect mix reads 0-100 %; the CC map names the other controls' parameters but not their values, so they stay numbers.
  • MX400 Owner's Manual 18-0446V-F, p. 12: the LCD shows the program's name, two at once in Dual Stereo

Gaps, and why

  • Back up: its System Exclusive is for Lexicon's MX-Edit only (MIDI chart, p. 45) and Lexicon has never published it; the unit has no dump of its own to start from the front panel, so backups go through MX-Edit's Backup.
  • Names from a backup: there is no backup Patchmark can take.
  • Read names from the hardware: the unit's SysEx is for MX-Edit only and undocumented, so there is no request to ask for names with.
  • Recognise: its MIDI chart lists no reply to being asked who it is: its SysEx is for MX-Edit only.
  • Follows its front panel: its MIDI chart says it transmits no Program Change, so choosing a program with its knob can't be followed.
  • The printed Stereo list names two programs ACOUSTIC PLATE (18 and 19) and two IN REVERSE (31 and 99); the template keeps them as printed.

Status

Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.

Feature Status
Recall To test
Factory names To test
Factory tags To test

Questions

Does Patchmark edit the MX400 Stereo's sounds?

Yes, its sound controls: it turns the MX400 Stereo's 39 controls over MIDI CC and NRPN, from the Patch tab and the DAW's lanes. It doesn't edit whole patches over SysEx: it lists them by name, recalls them and keeps the names, and the patches themselves stay on the unit.

How many MX400 Stereo patches does it know?

198 numbers, in 2 banks (Factory, User), numbered 001–099. 99 of them carry the maker's names.

Can it back up the MX400 Stereo?

Not yet: its System Exclusive is for Lexicon's MX-Edit only (MIDI chart, p. 45) and Lexicon has never published it; the unit has no dump of its own to start from the front panel, so backups go through MX-Edit's Backup.

Does it read the patch names from the MX400 Stereo?

Not yet: the unit's SysEx is for MX-Edit only and undocumented, so there is no request to ask for names with.

Has it been checked on a real MX400 Stereo?

Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).

Which DAWs does it work in with the MX400 Stereo?

Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.

For beta testers

If you own a Lexicon MX400 Stereo, these checks help most (Beta testing):

  • With the unit in Stereo, do patch 001 in Factory and patch 001 in User both recall?
  • Do programs 19 and 99 show the names the list prints (ACOUSTIC PLATE and IN REVERSE again), or other names?

Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.

This manual is for version 0.9.9.