Manual contents
For version 0.9.9 · beta · Change
Sequential OB-6
| Question | Answer |
|---|---|
| Does Patchmark work with the OB-6? | Documented, untested |
| Reads its patch names, from the unit or a backup? | Documented, untested |
| Backs it up over SysEx? | Documented, untested |
| Turns its sound controls (MIDI CC and NRPN)? | Documented, untested |
| Edits whole patches over SysEx? | No |
Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Sequential OB-6's patches inside your DAW project (1000 numbers in 10 banks, 1000 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. Patchmark can also back the unit up over SysEx, read its patch names from it and recognise it when asked who it is, following the maker's documentation; this is not yet checked on a unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.
Leave manual off: with live panel mode on, the OB-6 doesn't change programs or banks.
Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.
The Sequential OB-6 template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.
What Patchmark does with it
- Recall: 100 patches in each of 10 banks (0 User, 1 User, 2 User, 3 User, 4 User, 5 Factory, 6 Factory, 7 Factory, 8 Factory, 9 Factory), numbered by the hundred, bank and patch together, as the unit shows them (000–999). Patchmark sends Bank Select LSB (CC 32), then Program Change, on MIDI channel 1 to start with.
- Factory names: 1000 patches in 10 of the 10 banks carry the maker's own names.
- Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
- Back up and restore: start a backup in Patchmark, then on the unit: Globals, Pgm Dump: choose usr (all user banks) and press write. (SysEx backup and restore)
- Names from a backup: Names… on a backup reads the patch names out of it.
- Read names from the hardware: Library ▸ Read names from hardware… asks the unit for its patches and reads their names, no backup needed: its 5 user banks, all or one.
- Rename on hardware: after you rename a patch in user banks 0–4, Patchmark can write the new name into the unit's memory too, and keep a backup first (taken from the maker's manual, not yet tried on a unit). (Renaming a patch)
- Recognise: the unit answers when asked who it is, and Device setup offers this template.
- Follows its front panel: choosing a patch on the unit moves the current patch in the list; on the unit, Globals ▸ MIDI Out must name the port Patchmark listens on (MIDI or USB) (When you change the patch on the device).
- Names on the unit: the unit shows numbers only, so the names you see are Patchmark's; in user banks 0–4 a new name can still be written into the unit's memory (above).
Connecting it
- Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
- The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
- For a backup, or reading names: Globals ▸ MIDI SysEx must name the port in use (MIDI or USB).
- To follow the unit's front panel: Globals ▸ MIDI Out must name the port Patchmark listens on (MIDI or USB).
- Insert the plugin as an audio effect on any track; the audio passes through untouched.
Sound controls
The Patch tab turns 65 of the OB-6's sound controls, in the Oscillators, Portamento, Filter, Loudness Env, Filter Envelope, LFO, Effects, Voice and Arpeggiator sections, and puts any on a DAW lane (Sound controls).
On the OB-6, Globals: Param Rcv set to NRPN.
Values on the Patch tab
Of its 65 controls, 63 show their values as the OB-6's manual gives them (units, names, %), and 2 show the plain number it takes.
Plain numbers: the manual lists 13 effect types, but its parameter table gives FX 1 Type 0-5 and FX 2 Type 0-9, so which number is which type isn't documented.
Sources
- Sequential OB-6 Operation Manual v1.2 (Feb 2021, DSI-10139R), for the keyboard and the desktop module: p. 2 'Sound Banks' (1000 programs, 10 banks of 100; banks 0-4 user, 5-9 factory and permanent; as shipped 000-499 are identical to 500-999); Appendix C pp. 78-79 'Received Channel Messages' (Program Change 0-99 within the current bank; Bank Select on CC 32, values 0-9). No global turns Program Change reception off (pp. 11-15), but with Manual (live panel mode) on, programs and banks can't be changed (p. 5, p. 59). The factory MIDI channel is not documented (the global reset, p. 66, lists no values). Numbering 000-999 as the unit shows it (p. 2); factory names from the OB-6 Factory Presets list (2016, one bank per page, pp. 1-5), banks 5-9 as banks 0-4, transcribed as printed: 263 'Phased String Ensemb' is cut in the list itself, and 265 'A Striking ReSEMblance' is longer than the unit's 20 characters (p. 85), so the unit's own copy is shorter. User banks 0-4 can be overwritten on the unit; a name you give in the plugin always wins. The list's curly quotes are plain ones (315 'Vowels '83', 433 '12" Piano'), as the unit stores characters 32-125 (p. 85). Tags: from the program's name, a best guess, since Sequential publishes no categories; a name that says nothing about its sound is tagged Poly, the OB-6's own polyphonic character. Unconfirmed: no OB-6 has been checked.
- OB-6 Operation Manual, Appendix C: Program Parameter Data pp. 94-95 (PDF pages) Values as the unit shows them: switches Off/On; VCO Freq in semitones over five octaves, shown as notes C0-C5; Detune and the amounts 0-254 centred on 127; names from the manual's Portamento, Key Assign Modes, LFO and Arpeggiator sections; FX types left as numbers (the manual's 13 types don't match the table's ranges); the rest 0-100 %.
- OB-6 Operation Manual v1.2: p. 4, the bank/program display is numeric (LED); names exist only in the program data (p. 85, NRPN 236-255) and no screen shows them
- OB-6 Operation Manual v1.2: p. 15 Globals 'Pgm Dump' (Prg, Ten, Ban, usr, All; programs load back into the same bank and program) and p. 64 'Exporting Programs and Banks'; p. 88 Program Data Dump F0 01 2E 02 <bank 0-9> <program 0-99> <1171 bytes packed MS bit> F7 (1178 bytes); p. 13 Global 'MIDI SysEx' must name the port in use (MIDI or USB).
- OB-6 Operation Manual v1.2, p. 87: Request Program Dump F0 01 2E 05 <bank 0-9> <program 0-99> F7, answered with a Program Data Dump (p. 88). The Global MIDI SysEx setting must name the port in use (p. 13). No pause between requests is documented; each waits for its reply.
- OB-6 Operation Manual v1.2, pp. 88-89: Program Data Dump F0 01 2E 02 <bank> <program> <1171 bytes packed seven in eight, the first byte of each group holding the others' top bits, the first one's in bit 0>, the Prophet-6's scheme. The name is 20 characters, values 32-125 (Name 0-19, NRPN 236-255, p. 85); the manual gives no dump offsets, so 107 comes from the KnobKraft librarian's OB-6 adaptation (DSI_OB6.py, name_position 107, tested on the factory dump OB6_Programs_v1.01.syx), as for the Prophet-6. To confirm on a unit.
- OB-6 Operation Manual v1.2, Appendix C p. 86, Device Inquiry reply F0 7E <channel> 06 02 01 <OB-6 ID> 01 00 00 <version> F7. The manual prints the OB-6 ID there as 2D, the Prophet-6's, while every OB-6 request and dump uses 2E (pp. 87-88); 2E is taken, as the KnobKraft librarian's OB-6 adaptation (DSI_OB6.py) recognises it. To confirm on a unit.
Gaps, and why
- None known.
Status
Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.
| Feature | Status |
|---|---|
| Recall | To test |
| Factory names | To test |
| Factory tags | To test |
| Back up | To test |
| Restore | To test |
| Names from a backup | To test |
| Read names from the hardware | To test |
| Rename on hardware | To test |
| Recognise | To test |
| Follows its front panel | To test |
Questions
Does Patchmark edit the OB-6's sounds?
Yes, its sound controls: it turns the OB-6's 65 controls over MIDI CC and NRPN, from the Patch tab and the DAW's lanes. It doesn't edit whole patches over SysEx: it lists them by name, recalls them and keeps the names, and the patches themselves stay on the unit.
How many OB-6 patches does it know?
1000 numbers, in 10 banks, numbered by the hundred, bank and patch together, as the unit shows them (000–999). 1000 of them carry the maker's names.
Can it back up the OB-6?
Not yet checked on a unit. Following the maker's documentation, it backs the unit up over SysEx: start a backup in Patchmark, then on the unit: Globals, Pgm Dump: choose usr (all user banks) and press write.
Does it read the patch names from the OB-6?
Not yet checked on a unit. Following the maker's documentation, Library ▸ Read names from hardware… asks the OB-6 for its patches and reads their names.
Has it been checked on a real OB-6?
Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).
Which DAWs does it work in with the OB-6?
Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.
For beta testers
If you own a Sequential OB-6, these checks help most (Beta testing):
- Rename a patch in user banks 0–4 answering Rename on hardware: does Read names from hardware give the new name after a power cycle? Was the backup there?
- Which OS version?
- Does Recognise find it (the manual's reply byte looks like a misprint)?
- Do banks 0 and 5 both recall, and does Read names from hardware fill bank 5 with its factory names?
- Does a renamed program still sound the same?
Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.
This manual is for version 0.9.9.