Patchmark‹ All plug-ins
Manual contents
For version 0.9.7 · beta · Change

You're reading the manual for Patchmark 0.9.7. Go to this page for 0.9.9

Devices

Eventide H3000 D/SX

Question Answer
Does Patchmark work with the H3000 D/SX? Documented, untested
Reads its patch names, from the unit or a backup? No
Backs it up over SysEx? Documented, untested
Edits its parameters? No

Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Eventide H3000 D/SX's patches inside your DAW project (1000 numbers in 10 banks, 294 of them with the maker's names) and recalls one by sending NRPN 8197 (CC 99 and 98, then CC 6 and 38) for the bank, then Program Change. Patchmark can also back the unit up over SysEx, following the maker's documentation; this is not yet checked on a unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.

The presets Eventide's preset list gives the D/SX, by number and name. A recall sends the program number's hundreds digit as NRPN 8197, then the last two digits as a Program Change: patch 242 is NRPN 8197 = 2, then Program Change 42. On the unit, set MIDI Program Load (FUNCTION four times) to Pgm=ID and Pgm=On, and turn Seq=On (FUNCTION five times) so it takes the bank over MIDI. Patchmark backs up the user programs by asking the unit for them, or from the unit's own Dump Pre.

Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.

The Eventide H3000 D/SX template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.

What Patchmark does with it

  • Recall: 100 patches in each of 10 banks (000-099 User, 100-199 Factory, 200-299 Factory, 300-399 Factory, 400-499 Factory, 500-599, 600-699, 700-799 Factory, 800-899 Factory, 900-999 Factory), numbered by the hundred, bank and patch together, as the unit shows them (000–999). Patchmark sends NRPN 8197 (CC 99 and 98, then CC 6 and 38) for the bank, then Program Change, on MIDI channel 1 to start with.
  • Factory names: 294 patches in 7 of the 10 banks carry the maker's own names.
  • Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
  • Back up and restore: start a backup in Patchmark, then on the unit: FUNCTION five times, Dumps, then Dump Pre. (SysEx backup and restore)
  • Follows its front panel: choosing a patch on the unit moves the current patch in the list; on the unit, Seq=On (FUNCTION five times), with Enables leaving transmit Pgm=On. Expert MIDI's Bank (FUNCTION three times, Expert, more, more) can stay at SyX, the factory setting, or be Par: Patchmark reads the bank either way (When you change the patch on the device).
  • Names on the unit: the unit shows patch names, so renaming a patch here renames it in Patchmark only, and Patchmark says so the first time (Renaming a patch).

Connecting it

  • Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
  • The unit must receive Program Change and NRPN 8197 (CC 99 and 98, then CC 6 and 38) for the bank; where the maker's manual says how to set that, it is cited in Sources below.
  • For a backup, or reading names: keep Expert MIDI (FUNCTION three times, Expert) on SysX=On, the factory setting, or the unit ignores a restore.
  • To follow the unit's front panel: Seq=On (FUNCTION five times), with Enables leaving transmit Pgm=On. Expert MIDI's Bank (FUNCTION three times, Expert, more, more) can stay at SyX, the factory setting, or be Par: Patchmark reads the bank either way.
  • Insert the plugin as an audio effect on any track; the audio passes through untouched.

Sound controls

The Patch tab turns 12 of the H3000 D/SX's sound controls, in the System, Soft Functions and Function Generator sections, and puts any on a DAW lane (Sound controls). Each of its 15 algorithms adds its own controls while one of its programs plays: a factory program's algorithm comes with the template, a user program's you choose on the Patch tab's Algorithm line.

On the H3000 D/SX, MIDI Receive Enable on.

Values on the Patch tab

Of its 214 controls, 205 show their values as the H3000 D/SX's manual gives them (units, names, %), 1 follow a guess, and 8 show the plain number it takes.

Plain numbers: the manual gives them as a bare number (glide, gate and trigger speeds, the stutter counts and sweeps, the String Modeller's tone controls, the filters' Q 1 to 1000), so the number is what the unit shows; the function generator's type is only a 'position as scanned' in Appendix C, with no list to name it by.

Guessed, not given by the manuals: if you own a H3000 D/SX, check these against the unit's display and tell us what it shows (Beta testing):

  • Key: that the twelve keys go C to B in the order listed.

Sources

  • Eventide H3000 Ultra-Harmonizer Instruction Manual (models combined in one manual, January 1996; a scan, read from the page images): the preset list (Quick Reference, pp. 155-201 of the manual, PDF pp. 135-182), the names as printed and the UNIT column for which model has which preset: 'Basic effect algorithms are found between numbers 100 and 123. Factory programs are found between numbers 150 and 999. Gaps in the numbered sequence are intentional.' The 100-123 algorithms aren't listed by number, so those slots are unnamed. Appendix C, pp. 31-32: the Program Bank number is NRPN 8197 (2005H), value 0-9 the program number's first digit (10 = last edit), and the Program Change gives the last two digits (0-99); patch x00-x99 sends Program Change 0-99. A parameter changes only when its value's LSB (CC 38) arrives, so a recall sends CC 99, 98, 6 and 38. p. 33: a Program Change 100-127 loads program 100-127 whatever the bank. Using MIDI pp. 19-21: a Program Change loads the program of that number with MIDI Program Load (FUNCTION four times) on Pgm=ID and Pgm=On; the bank is changed over MIDI as the Sequencing section says: with Seq=On (FUNCTION five times) the unit receives and sends program and parameter changes and forces Pgm=ID and Pgm=On. Appendix C pp. 32-33 and Appendix B p. 30: when a program is loaded with Seq=On the unit sends 'first a Bank Select and then a MIDI Program Change'; that Bank Select is a Universal SysEx message (F0 7F nn 02 01 0c 00 00 00 00 0b 00 F7) with Expert MIDI's Bank=SyX, the factory setting, or NRPN 8197 with Bank=Par, and the unit responds to either. 0-99 are the user programs. Tags: from each preset's algorithm and description in the list. The MIDI chart (Appendix D, p. 34) documents no identity reply. Unconfirmed: no unit has been checked. This template holds the presets marked D/SX or All Units.
  • Eventide H3000 series manual, Appendix C MIDI Parameter Numbers (PDF pp. 37-38); each algorithm's parameters from its chapter (pp. 45-123, PDF pp. 51-129), the whole-number ones with one number each, every value 14-bit two's complement; each factory program's algorithm from the preset list's ALGORITHM column (MOD FACTORY says not which, so left to the musician) Values, as the manual shows them: Appendix C gives the attenuators 0 to -48 (Off), the bypass relay 0 Bypassed and 1 Through, the soft function scalers 50 times the shown value, the function frequency in Hz times 100 and its amplitude in % of full scale; the function type is only a 'position as scanned', so it stays a number. Each algorithm's parameter list gives the unit beside each range: mixes, feedbacks, levels, widths and the master controls in %, delays, lengths and splices in ms, pitch in cents, Band Delay's frequency in notes, cutoffs and modulation amounts in Hz (mod factory two's in cents), thresholds and the In and Out levels in dB, tempo in BPM. Where it gives a bare 0 to 100 (glide and gate speeds, the stutter sweeps, the String Modeller's tone controls) the number is what the unit shows. Added, as the manual numbers them: Diatonic Shift's Key (C to B) and the Phaser's Sweep Mode (: 0 sweep, 1 envelope, 2 adsr), Envelope Channel and Envelope Decay Shape.
  • H3000 Instruction Manual, p. 2, The Front Panel and Controls, item 11 (Display): the top line shows the program number and name
  • H3000 Instruction Manual, Using MIDI pp. 21-22: FUNCTION five times, Dumps, Dump Pre sends all the user programs as Eventide System Exclusive (Appendix E p. 35: maker 1CH, model 60H, the device number set in Expert MIDI, p. 29); a preset dump received replaces the unit's user programs, and Expert MIDI's SysX=On (the factory setting) lets it in. Appendix E also documents dump requests (DUMPPRESETS: F0 1C 60 <device> 00 7C 46 45 34 32 43 30), but not the dump's format: a dump is kept as received and sent back as it came.

Gaps, and why

  • Names from a backup: Eventide documents how to ask for a dump but not the dump's format, so where it keeps a program's name isn't known.
  • Read names from the hardware: the manual documents asking for the current program or all user programs at once, not one stored program, and not where a dump keeps its name.
  • Recognise: the MIDI chart and appendices document no reply to being asked who it is.
  • Programs 100–123 are the basic algorithms; the preset list doesn't number them one by one, so they're unnamed.
  • Eventide's list leaves gaps in the numbering on purpose; a number with no preset recalls nothing.
  • Eventide's preset list gives the D/SX no presets in 500–699: those banks are unnamed. A unit upgraded with more programs (the manual says any H3000 can be, except for the H3500's own presets) recalls them by number, without names.
  • Some names are printed longer than 16 characters; the unit may show them shortened.
  • A backup is kept as received: Eventide documents the dump requests but not the dump's format. Back up now sends the message Eventide documents for asking the unit for all its user programs (DUMPPRESETS, device number 0, the factory setting); a unit set to another device number, or one that doesn't answer, is backed up by pressing Dump Pre on it. Restoring sends the dump back, which replaces all the unit's user programs at once.

Status

Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.

Feature Status
Recall To test
Factory names To test
Factory tags To test
Back up To test
Restore To test
Follows its front panel To test

Questions

Does Patchmark edit the H3000 D/SX's sounds?

Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. It turns the H3000 D/SX's sound controls from the Patch tab and the DAW's lanes, over MIDI.

How many H3000 D/SX patches does it know?

1000 numbers, in 10 banks, numbered by the hundred, bank and patch together, as the unit shows them (000–999). 294 of them carry the maker's names.

Can it back up the H3000 D/SX?

Not yet checked on a unit. Following the maker's documentation, it backs the unit up over SysEx: start a backup in Patchmark, then on the unit: FUNCTION five times, Dumps, then Dump Pre.

Does it read the patch names from the H3000 D/SX?

Not yet: the manual documents asking for the current program or all user programs at once, not one stored program, and not where a dump keeps its name.

Has it been checked on a real H3000 D/SX?

Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).

Which DAWs does it work in with the H3000 D/SX?

Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.

For beta testers

If you own an Eventide H3000 D/SX, these checks help most (Beta testing):

  • Which model and software version is it?
  • Does patch 242 (NRPN 8197 = 2, then Program Change 42) load 242 RICH CHORUS?
  • Do the names in the patch list match the ones on the unit?
  • Does a recall work with Seq=Off (MIDI Program Load on Pgm=ID and Pgm=On), or only with Seq=On?
  • With Seq=On, does loading a program on the unit move Patchmark's current patch to it, with Bank=SyX and with Bank=Par?
  • Start a backup without touching the unit: does the backup arrive and get saved? If not, start one and press FUNCTION five times, Dumps, Dump Pre on the unit: is that backup saved? After changing a user program, does restoring it bring the program back?
  • On which MIDI channel does it listen?
  • Send us a Dump Edit of one of your named user programs: it shows where the H3000 keeps a name, for names from a backup. (How and where)
  • Do the guessed values under Values on the Patch tab match what the unit shows?

Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.

This manual is for version 0.9.7.