Patchmark‹ All plug-ins
Manual contents
For version 0.9.7 · beta · Change

You're reading the manual for Patchmark 0.9.7. Go to this page for 0.9.9

Devices

Lexicon MPX1 V1.00

Question Answer
Does Patchmark work with the MPX1 V1.00? Documented, untested
Reads its patch names, from the unit or a backup? Documented, untested
Backs it up over SysEx? Documented, untested
Edits its parameters? No

Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Lexicon MPX1 V1.00's patches inside your DAW project (250 numbers in 3 banks, 200 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. Patchmark can also back the unit up over SysEx, read its patch names from it and recognise it when asked who it is, following the maker's documentation; this is not yet checked on a unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.

The MPX1 with its original software, version 1.00. Version 1.10 re-ordered the presets: use the MPX1 template for a unit that has been updated.

Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.

The Lexicon MPX1 V1.00 template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.

What Patchmark does with it

  • Recall: 250 patches in 3 banks (1-100, 101-200, User 201-250), from 50 to 100 in a bank, numbered 001–100. Patchmark sends Bank Select LSB (CC 32), then Program Change, on MIDI channel 1 to start with.
  • Factory names: 200 patches in 1-100, 101-200 carry the maker's own names.
  • Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
  • Back up and restore: start a backup in Patchmark, then on the unit: System, MIDI, Dump: choose All Programs. (SysEx backup and restore)
  • Names from a backup: Names… on a backup reads the patch names out of it.
  • Read names from the hardware: Library ▸ Read names from hardware… asks the unit for its patches and reads their names, no backup needed: its one bank, User 201-250.
  • Rename on hardware: after you rename a patch in the User 201-250 bank, Patchmark can write the new name into the unit's memory too, and keep a backup first (taken from the maker's manual, not yet tried on a unit). (Renaming a patch)
  • Recognise: the unit answers when asked who it is, and Device setup offers this template.
  • Follows its front panel: choosing a patch on the unit moves the current patch in the list; on the unit, System ▸ MIDI ▸ Transmit must be on the Device's MIDI channel (1, as shipped) (When you change the patch on the device).
  • Names on the unit: the unit shows patch names; renaming a patch here renames it in Patchmark, and in the User 201-250 bank it can rename it on the unit too (above).

Connecting it

  • Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
  • The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
  • For a backup, or reading names: System ▸ MIDI ▸ SysEx must be On with Receive Device ID 0, as shipped; Memory Protect Off for a rename.
  • To follow the unit's front panel: System ▸ MIDI ▸ Transmit must be on the Device's MIDI channel (1, as shipped).
  • Insert the plugin as an audio effect on any track; the audio passes through untouched.

Sound controls

No list comes with the MPX1 V1.00: add its controls on the Patch tab with Add control… (Sound controls).

On the MPX 1, each program's Dynamic MIDI patches set which CC moves which parameter. Add the same CCs here with Add control, or Learn them.

The Patch tab reaches only what the MPX1 V1.00 maps to a CC or NRPN, not the parameters it edits over SysEx alone (What sound controls can reach).

Sources

  • Lexicon MPX 1 User Guide 070-11097 Rev 2 (1997): p. 2-6, p. 2-7 and p. 6-6, 200 presets and 50 user programs in three banks, 1-100, 101-200 and 201-250 (empty when shipped); p. 5-6 and p. 5-8, Pgm Change On by default, 'Program Change messages 0-99 correspond to MPX 1 programs 1-100', receive channel 1; p. 6-6, 'Controller 32 is used to select Banks'. The CC 32 values 0, 1 and 2, which offset Program Changes by 0, 100 and 200, are from the MPX 1 V1.10 MIDI Implementation Details 070-11835 Rev 1, p. 48 (the program_bank setting). The patches number 001-100 in each bank, so bank 101-200's 001 is program 101; the User bank holds 001-050, programs 201-250, and lists only those. Factory names for version 1.00, from the User Guide's Preset Summary, pp. 2-8 and 2-9, as printed (156 joined: 'Synthis izer'). A unit updated to 1.10 has its presets in other places: use the MPX1 template for it. These printed names are longer than the unit's 12 characters: 'Another Brick', 'Broken Speakr', 'Chorus Chambr', 'Fazer->DlyPan', 'IPS Tape Slap', 'L=Ptch R=Chmb', 'Open the Door', 'Touch Spinner'; they are kept as printed, as the unit's own spelling isn't documented. Tags: from each program's name, and from the effect blocks the V1.00 Preset Summary marks (G1 pp. 2-8 to 2-9: pitch, chorus, EQ, modulation, delay, reverb) where its name doesn't say; a reverb whose name gives no space is Hall. Unconfirmed: no unit has been checked.
  • MPX 1 User Guide p. 1-1 and p. 2-7: two rows of 16 characters, the upper one the running program's name; names are 12 characters (MIDI Implementation Details p. 32)
  • MPX 1 V1.10 MIDI Implementation Details 070-11835 Rev 1: p. 2 and p. 10, F0 06 09 <device ID>, Lexicon 06, MPX 1 09; pp. 23-25, Program Dump (844 bytes, the name at bytes 492-515). MPX 1 User Guide p. 5-10 and p. 6-8, the front panel's dumps (Current Pgm, All Programs, maps, chains, setups); SysEx receive is on by default, Receive ID 0 (p. 5-6, p. 5-9). A dump is kept as received. Read names: the Program Information request, MPX 1 MIDI Implementation Details 070-11835 p. 24; rename by the Program Dump, pp. 25-26; the sysex pauses 300 ms after each message it sends, for the unit's BUSY and READY handshakes (p. 20).
  • MPX 1 MIDI Implementation Details 070-11835, p. 24 (bytes counted from F0 as byte 1): Requests, class 06, name the class wanted in two nibbles and the program in four, then two unused nibbles, F0 06 09 <device ID> 06 0A 01 <program> 00 00 F7, whose example asks for program 8 with 08 00 00 00 00 00; 0A 01 asks for Program Information (1A), the program's name and its effects in 46 bytes, which a Program Dump's 844 would take 18 times longer to send. The program 0-249 (programs 1-250 on the unit) in four nibbles, low first, numbered on across the banks from 0, 100 and 200. Device ID 0, the unit's Receive Device ID when shipped (User Guide p. 5-6 and p. 5-9: System, MIDI, SysEx On, Options: Receive Device ID). The User bank asks only its 50 programs, 200-249. No reply time is given: the unit paces dumps with handshakes instead (p. 20). Unconfirmed: no MPX1 here, a beta tester confirms.
  • MPX 1 MIDI Implementation Details 070-11835, pp. 25-26, Program Dump: F0 06 09 <device ID> 1B, the program at bytes 6-9 (counted from F0 as byte 1; 5-8 counted from 0), the effects, routing and algorithms, then the name at bytes 492-515, 12 ASCII characters as nibbles, low first, 844 bytes in all. A front-panel Current Pgm dump, and the rename's request, send one; All Programs is taken to send one per program, which the documents don't say. Unconfirmed, as the request.
  • MPX 1 V1.10 MIDI Implementation Details 070-11835 Rev 1, p. 9: the Device Inquiry reply F0 7E <device ID> 06 02 06 00 00 09 00 <version> F7 (printed with F0 FE, a misprint for the universal 7E)

Gaps, and why

  • The CC 32 values 0, 1 and 2 come from the MIDI Implementation Details' description of a setting, not a table; the guide also says Bank Select can choose a MIDI map, without saying which value does.
  • Rename writes the user programs 201-250 only; the presets 1-200 are in the unit for good.
  • An empty user program's name isn't documented: Read names shows whatever the unit answers.
  • A few names are printed longer than the unit's 12 characters.

Status

Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.

Feature Status
Recall To test
Factory names To test
Factory tags To test
Back up To test
Restore To test
Names from a backup To test
Read names from the hardware To test
Rename on hardware To test
Recognise To test
Follows its front panel To test

Questions

Does Patchmark edit the MPX1 V1.00's sounds?

Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. Sound controls you add on the Patch tab it turns from there and the DAW's lanes.

How many MPX1 V1.00 patches does it know?

250 numbers, in 3 banks (1-100, 101-200, User 201-250), numbered 001–100. 200 of them carry the maker's names.

Can it back up the MPX1 V1.00?

Not yet checked on a unit. Following the maker's documentation, it backs the unit up over SysEx: start a backup in Patchmark, then on the unit: System, MIDI, Dump: choose All Programs.

Does it read the patch names from the MPX1 V1.00?

Not yet checked on a unit. Following the maker's documentation, Library ▸ Read names from hardware… asks the MPX1 V1.00 for its patches and reads their names.

Has it been checked on a real MPX1 V1.00?

Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).

Which DAWs does it work in with the MPX1 V1.00?

Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.

For beta testers

If you own a Lexicon MPX1 V1.00, these checks help most (Beta testing):

  • Rename a patch in the User 201-250 bank answering Rename on hardware: does the unit show the new name after a power cycle? Was the backup there?
  • Which software version does it run (Recognise shows it)?
  • Do programs 1, 101 and 201 recall?
  • Does Read names from hardware fill 1-100 and 101-200 with the names your unit shows, and 201-250 with your own?
  • Does loading a program on the unit move Patchmark's list to it?

Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.

This manual is for version 0.9.7.