Patchmark‹ All plug-ins
Manual contents
For version 0.9.7 · beta · Change

You're reading the manual for Patchmark 0.9.7. Go to this page for 0.9.9

Devices

Yamaha SPX900

Question Answer
Does Patchmark work with the SPX900? Documented, untested
Reads its patch names, from the unit or a backup? No
Backs it up over SysEx? Documented, untested
Edits its parameters? No

Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Yamaha SPX900's patches inside your DAW project (99 numbers, 50 of them with the maker's names) and recalls one by sending Program Change alone, no Bank Select. Patchmark can also back the unit up over SysEx and recognise it from a request it answers, following the maker's documentation; this is not yet checked on a unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.

Select Program Change bank D on the unit (UTILITY, MIDI control): its table resets at every power-on so that each Program Change recalls the memory of the same number, which is what this template sends. Patchmark backs the unit up from its own MIDI bulk dump and recognises it by asking for its system settings.

Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.

The Yamaha SPX900 template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.

What Patchmark does with it

  • Recall: 99 patches, numbered 001–099. Patchmark sends Program Change alone, no Bank Select, on MIDI channel 1 to start with.
  • Factory names: 50 patches in Memories carry the maker's own names.
  • Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
  • Back up and restore: start a backup in Patchmark, then on the unit: UTILITY (press it until BULK OUT 1 shows), ALL, then press STORE. (SysEx backup and restore)
  • Recognise: the unit answers a request that only reads from it, and Device setup offers this template (taken from the maker's manual, not yet tried on a unit).
  • Names on the unit: the unit shows patch names, so renaming a patch here renames it in Patchmark only, and Patchmark says so the first time (Renaming a patch).

Connecting it

  • Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
  • The unit must receive Program Change; where the maker's manual says how to set that, it is cited in Sources below.
  • For a backup, or reading names: set the rear MIDI THRU/OUT switch to OUT, so the dump leaves by that jack, and give bank D a MIDI channel (not OFF).
  • Insert the plugin as an audio effect on any track; the audio passes through untouched.

Sound controls

No list comes with the SPX900: add its controls on the Patch tab with Add control… (Sound controls).

On the SPX900, MIDI Parameter Control sets the CC of each of the two controllers, and each program what they move. Add the same CCs here with Add control, or Learn them.

The Patch tab reaches only what the SPX900 maps to a CC or NRPN, not the parameters it edits over SysEx alone (What sound controls can reach).

Sources

  • Yamaha SPX900 Owner's Manual (usa.yamaha.com; a scan, read with OCR and checked against the page images): p. 6, memories 1-50 preset (read-only) and 51-99 user; p. 28, four Program Change banks A-D, each with its own channel and a table from Program Change to memory, and bank D's table resets to 'PGM number = MEM number' at every power-on; the MIDI chart, p. Add-36, 'For program 1-128, memory 1-99 is selected' (the chart writes the memories with a number sign). So this template expects bank D: Program Change 0-98 recall memories 1-99. The manual gives no default channel; 1 is assumed. No Bank Select: Control Changes are parameter controls. Factory names from p. 6, as printed; 'MULTI (ECH&REV) 1', 'MULTI (ECH&REV) 2', 'MULTI (CHO&REV) 1', 'MULTI (CHO&REV) 2', 'MULTI (CHO&REV) 3', 'MULTI (SYM+REV) 1', 'MULTI (SYM+REV) 2', 'MULTI (SYM+REV) 3', 'MULTI (EXC&REV) 1', 'MULTI (EXC&REV) 2' run past the 16 characters of the LCD's top line, so the unit may show them shorter. Memories 51-99 are yours, so they have no names here. Tags: from each preset's family in the manual's contents (p. 1) and its name; a reverb whose name gives no space is Hall. Backup: p. 29, UTILITY's BULK OUT 1 sends ALL (every memory and the four Program Change banks) when STORE is pressed, out of the MIDI THRU/OUT jack with its rear switch on OUT; pp. Add-23 to Add-35, Yamaha SysEx F0 43 0n 7E with the format name 'LM 8636', received back as sent with 30 ms or more between messages (Add-35). Where a memory's title sits in a dump isn't documented, so the dump is kept as received and names aren't read from it. Recognise: the System Setup Data Bulk Dump Request F0 43 2n 7E 'LM 8636S' 20 F7 (Add-33, Add-34), answered with the System Setup bulk data, 'LM 8636S' (Add-29). Unconfirmed: no unit has been checked.
  • SPX900 Owner's Manual p. 3 and p. Add-39: a 16-character, 2-line LCD shows the program's title
  • SPX900 Owner's Manual p. 29: BULK OUT 1 sends ALL (every memory and the Program Change banks) when STORE is pressed, through MIDI THRU/OUT switched to OUT; p. Add-35: data sent back needs 30 ms or more between messages. Where a memory's title sits in a dump isn't documented: a dump is kept as received and sent back as it came.
  • SPX900 Owner's Manual pp. Add-29, Add-33 and Add-34: the System Setup Data Bulk Dump Request F0 43 2n 7E 'LM 8636S' 20 F7 only makes the unit send its System Setup bulk data, F0 43 0n 7E 00 19 'LM 8636S'; 8636 is the SPX900's own format. Asked on MIDI channels 1-16 (a request is received on the selected Program Change bank's channel). Unconfirmed: no SPX900 here.

Gaps, and why

  • Names from a backup: Yamaha doesn't document where a program's title sits in its dump; a tester's backup of a program whose title they know would show it.
  • Read names from the hardware: Yamaha doesn't document where a program's title sits in its dump; a tester's backup of a program whose title they know would show it.
  • Follows its front panel: its MIDI chart says it transmits no Program Change, so a memory chosen on the unit can't be followed.
  • Program Change 99-127 (patches beyond 099) do nothing documented: bank D maps Program Change to memory 1-99 only.
  • Banks A-C keep tables you set; their factory contents aren't documented.
  • A backup is kept as received: it holds every memory and the Program Change banks, and sending it back restores them.

Status

Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.

Feature Status
Recall To test
Factory names To test
Factory tags To test
Back up To test
Restore To test
Recognise To test

Questions

Does Patchmark edit the SPX900's sounds?

Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. Sound controls you add on the Patch tab it turns from there and the DAW's lanes.

How many SPX900 patches does it know?

99 numbers, numbered 001–099. 50 of them carry the maker's names.

Can it back up the SPX900?

Not yet checked on a unit. Following the maker's documentation, it backs the unit up over SysEx: start a backup in Patchmark, then on the unit: UTILITY (press it until BULK OUT 1 shows), ALL, then press STORE.

Does it read the patch names from the SPX900?

Not yet: Yamaha doesn't document where a program's title sits in its dump; a tester's backup of a program whose title they know would show it.

Has it been checked on a real SPX900?

Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).

Which DAWs does it work in with the SPX900?

Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.

For beta testers

If you own a Yamaha SPX900, these checks help most (Beta testing):

  • With Program Change bank D selected, do patches 001, 050 and 099 recall memories 1, 50 and 99?
  • Are the long names, such as MULTI (ECH&REV) 1, shortened on the display?
  • Start a backup, then on the unit: UTILITY until BULK OUT 1, ALL, press STORE. Is the backup saved? After changing memory 51, does restoring it bring the memory back?
  • Does Recognise find the unit, and on bank D's MIDI channel?
  • Send us that backup, with the title of memory 51: it shows where a dump keeps the titles, so Patchmark can read them. (How and where)

Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.

This manual is for version 0.9.7.