Yamaha REV500

Question Answer
Does Patchmark work with the REV500? Documented, untested
Reads its patch names, from the unit or a backup? No
Backs it up over SysEx? Documented, untested
Edits its parameters? No

Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Yamaha REV500's patches inside your DAW project (100 numbers, 100 of them with the maker's names) and recalls one by sending Program Change alone, no Bank Select. Patchmark can also back the unit up over SysEx and recognise it from a request it answers, following the maker's documentation; this is not yet checked on a unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.

The 100 user programs (HALL, ROOM, PLATE and SPECIAL, 25 each), recalled by Program Change alone and named as shipped. Yamaha doesn't document how the Program Change map is set at the factory, so this template assumes Program Change 1–100 recall them in order. If yours differs, set the map that way under UTILITY, MIDI PGM TABLE. Patchmark backs the unit up from its own MIDI bulk dump and recognises it by asking for its system settings.

Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.

The Yamaha REV500 template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.

What Patchmark does with it

  • Recall: 100 patches, numbered 001–100. Patchmark sends Program Change alone, no Bank Select, on MIDI channel 1 to start with.
  • Factory names: 100 patches in User carry the maker's own names.
  • Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
  • Back up and restore: start a backup in Patchmark, then on the unit: UTILITY (press it until MIDI BULK DUMP shows), REV TIME to ALL, then press STORE. (SysEx backup and restore)
  • Recognise: the unit answers a request that only reads from it, and Device setup offers this template (taken from the maker's manual, not yet tried on a unit).
  • Names on the unit: the unit shows patch names, so renaming a patch here renames it in Patchmark only, and Patchmark says so the first time (Renaming a patch).

Connecting it

  • Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
  • The unit must receive Program Change; where the maker's manual says how to set that, it is cited in Sources below.
  • For a backup, or reading names: set UTILITY's MIDI CHANNEL to a channel (not OFF), the one the Device uses.
  • Insert the plugin as an audio effect on any track; the audio passes through untouched.

Sound controls

The Patch tab turns 34 of the REV500's sound controls, in the Basic, Common, Reverb, Gate, Resonator, Dynamic Filter, Modulation, Tremolo and Echo sections, and puts any on a DAW lane (Sound controls).

Values on the Patch tab

Of its 34 controls, 9 show their values as the REV500's manual gives them (units, names, %), 9 follow a guess, and 16 show the plain number it takes.

Plain numbers: the list gives these in ms, seconds, Hz, dB, degrees or % over ranges the CC is scaled to on a curve the manual doesn't give (HPF THRU, 20 Hz to 1 kHz, for one), so the number is the CC's.

Guessed, not given by the manuals: if you own a REV500, check these against the unit's display and tell us what it shows (Beta testing):

  • Diffusion: that the settings share the CC's 0-127 evenly, each sent as the middle of its share.
  • Filter Offset: that the settings share the CC's 0-127 evenly, each sent as the middle of its share.
  • Filter Reso: that the settings share the CC's 0-127 evenly, each sent as the middle of its share.
  • Filter Sens: that the settings share the CC's 0-127 evenly, each sent as the middle of its share.
  • Gate Detect: that the settings share the CC's 0-127 evenly, each sent as the middle of its share.
  • Liveness: that the settings share the CC's 0-127 evenly, each sent as the middle of its share.
  • Lo-Ratio: that the settings share the CC's 0-127 evenly, each sent as the middle of its share.
  • Resonator Sens: that the settings share the CC's 0-127 evenly, each sent as the middle of its share.
  • Tremolo Wave: that the settings share the CC's 0-127 evenly, each sent as the middle of its share.

Sources

  • Yamaha REV500 Operation Manual (the PDF's text, checked against its pages): pp. 3-7, four program types, HALL, ROOM, PLATE and SPECIAL, of 25 programs each, in a PRESET (read-only) and a USER memory; 'When you first use the REV500, you will find that both memory areas contain the same selection of programs' (p. 3), and the Preset Program List gives their names (pp. 4-7), every one matched here. p. 16, one MIDI Program Change map assigns REV500 programs (eight banks of 25: the four types, preset and user) to Program Change 1-128; p. 15, initialising (STORE held at power-on) restores it to factory condition. The MIDI chart, Add-3: 'For program 1 - 128, REV500 program is selected', and no Program Change is transmitted. The map's factory contents aren't documented; the example screen on p. 16 shows Program Change 1 = HALL/U 1. So this template assumes that Program Change 1-100 recall the user programs in order: HALL 1-25 (patches 001-025), ROOM 1-25 (026-050), PLATE 1-25 (051-075), SPECIAL 1-25 (076-100), named as shipped. The device page says how to set the map that way. No Bank Select. The MIDI channel can be 1-16 or OMNI (p. 16); 1 is assumed. Tags: the program type, and the effect its Effect Type column (REV+CHO, REV->FLG, REV->GATE, ECHO->REV...) or its name names. Backup: p. 17, UTILITY's MIDI BULK DUMP sends ALL (system setup, every user program and the program table) when STORE is pressed, on the unit's MIDI channel; MIDI data format Add-1 and Add-2: Yamaha SysEx F0 43 0n 7E, program bulk data 'LM 8A99M' with the program number 1-100 and 62 data bytes, received back as sent. Where a program's title sits in those bytes isn't documented, so the dump is kept as received and names aren't read from it. Recognise: the System Setup bulk dump request F0 43 2n 7E 'LM 8A99S' 20 F7 (Add-2), answered with the System Setup bulk data, 'LM 8A99S' (Add-1). Unconfirmed: no unit has been checked.
  • Yamaha REV500 Owner's Manual, MIDI Controller Numbers and the Internal Parameter List (PDF pp. 13-17) Values as the unit shows them: the controls the Internal Parameter List gives 0-100 % (and the ER and Effect levels) read 0-100 %, taking the CC as scaled over that range. Settings the internal parameter list gives as a short scale or list (Lo-Ratio 0.1-2.4, Diffusion and Liveness 0-10, Gate Detect PRE/POST, the resonator and filter sensitivities, offset and resonance, Tremolo Wave SINE/TRI/SQR) share the CC's range evenly.
  • REV500 Owner's Manual p. 1, the NUMBER keys: the number and title of the selected program are shown in the LCD
  • REV500 Operation Manual p. 17: MIDI BULK DUMP, ALL sends the system setup data, every user program and the program table when STORE is pressed; Add-1 and Add-2: Yamaha SysEx, received back as sent. Where a program's title sits in a dump isn't documented: a dump is kept as received and sent back as it came.
  • REV500 Operation Manual, MIDI data format Add-1 and Add-2: the System Setup bulk dump request F0 43 2n 7E 'LM 8A99S' 20 F7 only makes the unit send its System Setup bulk data, F0 43 0n 7E 00 4C 'LM 8A99S'; 8A99 is the REV500's own format. Asked on MIDI channels 1-16. Unconfirmed: no REV500 here.

Gaps, and why

  • Names from a backup: Yamaha doesn't document where a program's title sits in its dump; a tester's backup of a program whose title they know would show it.
  • Read names from the hardware: Yamaha doesn't document where a program's title sits in its dump; a tester's backup of a program whose title they know would show it.
  • Follows its front panel: its MIDI chart says it transmits no Program Change, so a program chosen on the unit can't be followed.
  • The Program Change map's factory contents aren't documented: the template assumes Program Change 1–100 recall the user programs HALL 1–25, ROOM 1–25, PLATE 1–25 and SPECIAL 1–25. Set the map that way if yours differs.
  • The preset programs are reached only through a map you set; the user programs start as copies of them.
  • A backup is kept as received: it holds the system settings, every user program and the Program Change map, and sending it back restores all three.

Status

Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.

Feature Status
Recall To test
Factory names To test
Factory tags To test
Back up To test
Restore To test
Recognise To test

Questions

Does Patchmark edit the REV500's sounds?

Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. It turns the REV500's sound controls from the Patch tab and the DAW's lanes, over MIDI.

How many REV500 patches does it know?

100 numbers, numbered 001–100. 100 of them carry the maker's names.

Can it back up the REV500?

Not yet checked on a unit. Following the maker's documentation, it backs the unit up over SysEx: start a backup in Patchmark, then on the unit: UTILITY (press it until MIDI BULK DUMP shows), REV TIME to ALL, then press STORE.

Does it read the patch names from the REV500?

Not yet: Yamaha doesn't document where a program's title sits in its dump; a tester's backup of a program whose title they know would show it.

Has it been checked on a real REV500?

Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).

Which DAWs does it work in with the REV500?

Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.

For beta testers

If you own a Yamaha REV500, these checks help most (Beta testing):

  • On a fresh or initialised unit, what does the MIDI PGM TABLE hold: does Program Change 1 recall HALL/U 1, 26 ROOM/U 1, 76 SPECIAL/U 1?
  • Do patches 001, 050 and 100 recall HALL 1, ROOM 25 and SPECIAL 25?
  • Start a backup, then on the unit: UTILITY until MIDI BULK DUMP, REV TIME to ALL, press STORE. Is the backup saved? After changing a user program, does restoring it bring the program back?
  • Does Recognise find the unit, and on the right MIDI channel?
  • Send us that backup, with the title of user program HALL 1: it shows where a dump keeps the titles, so Patchmark can read them. (How and where)
  • Do the guessed values under Values on the Patch tab match what the unit shows?

Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.