Lexicon PCM70
| Question | Answer |
|---|---|
| Does Patchmark work with the PCM70? | Yes, checked on a unit |
| Reads its patch names, from the unit or a backup? | Yes, checked on a unit |
| Backs it up over SysEx? | Yes, checked on a unit |
| Edits its parameters? | No |
Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Lexicon PCM70's patches inside your DAW project (93 numbers, 43 of them with the maker's names) and recalls one by sending Program Change alone, no Bank Select. Patchmark can also back the unit up over SysEx, read its patch names from it and recognise it from a request it answers, as checked on a unit. Recall is confirmed on a real unit: recalled on the maker's own unit, October 2026.
The PCM70 with software version 1.x or 2.00 and their 43 factory presets. Version 3 changed the presets: use the PCM70 V3 template for a unit that has been updated.
Readiness: Tested. Tried on our own units.
What Patchmark does with it
- Recall: 93 patches, numbered as the unit shows them, row and column. Patchmark sends Program Change alone, no Bank Select, on MIDI channel 1 to start with.
- Factory names: 43 patches in Programs carry the maker's own names.
- Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
- Back up and restore: start a backup in Patchmark, then on the unit: the front-panel 'Send Registers' function. (SysEx backup and restore)
- Names from a backup: Names… on a backup reads the patch names out of it.
- Read names from the hardware: Library ▸ Read names from hardware… asks the unit for its patches and reads their names, no backup needed: its one bank, Programs.
- Rename on hardware: after you rename a patch in the registers R0.0–R4.9 (the presets stay as they are), Patchmark can write the new name into the unit's memory too, and keep a backup first. (Renaming a patch)
- Recognise: the unit answers a request that only reads from it, and Device setup offers this template.
- Follows its front panel: choosing a patch on the unit moves the current patch in the list (When you change the patch on the device).
- Names on the unit: the unit shows patch names; renaming a patch here renames it in Patchmark, and in the registers R0.0–R4.9 (the presets stay as they are) it can rename it on the unit too (above).
Connecting it
- Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
- The unit must receive Program Change; where the maker's manual says how to set that, it is cited in Sources below.
- For a backup, or reading names: the unit must send and accept SysEx; its manual says where that is switched on.
- Insert the plugin as an audio effect on any track; the audio passes through untouched.
Sound controls
No list comes with the PCM70: add its controls on the Patch tab with Add control… (Sound controls).
On the PCM70, each register's Dynamic MIDI patches set which CC moves which parameter. Add the same CCs here with Add control, or Learn them.
The Patch tab reaches only what the PCM70 maps to a CC, not the parameters it edits over SysEx alone. Patchmark70 edits them all (What sound controls can reach).
Sources
- Lexicon PCM 70 Owner's Manual, Revision 2.00 (software versions 1.x and 2.00): Table 2.1, the factory program matrix, names as printed (0.5 'SPIM ECHOES'), 43 presets in rows 0-6; row 7's control programs 7.0 and 7.1 are past Program Change 119 and left out. Confirmed on the maker's own unit, October 2026: 0.0 is 'Chorus' and there is no 1.9. Program Change and numbering from the Version 3.00 Owner's Manual (P/N 070-04971 Rev 1.1): p. 3-8 control parameter 1.2 PGM CHNG (FIX: Program Change 0-49 load registers 0.0-4.9, 50 upward presets 0.0 upward); p. 5-3 remote selection; p. 6-2 MIDI Implementation Chart, note 2 (Program Change 50-119 = programs 0.0-6.9; no Bank Select). Assumes PGM CHNG is set to FIX; the factory MIDI channel is not documented. Numbering as the unit shows it: registers R0.0-R4.9, presets P0.0-P6.9; a preset row's places past its last preset hold nothing on the unit, so they are missingPatches. Tags: by the program matrix's rows and the preset's name. The register dump is described from the Version 3.00 manual; version 2.00 added register transfer, and two units with software before 3.00 send the same layout ( B1).
- PCM 70 Owner's Manual, software version 3.00: p. 2-2 'A Unique Name for Every Program' and p. 2-3 'How to Select a Program', the display shows the program name; p. 8-3, 16-digit alphanumeric fluorescent display
- PCM 70 Owner's Manual, Software Version 3.00: p. 6-4 section I.A register dump F0 06 00 <000cnnnn: c 1 = stored register, nnnn = channel> <register> 02 4E <334 nibbles> <sumcheck> F7 (343 bytes), sent on request or via the front-panel 'Send Registers' diagnostic (section II.A); 30 ms between stored-register messages; the sumcheck's algorithm is not given: a backup keeps it as received, and a rename recomputes it as the low 7 bits of the nibbles' sum, as a backup of the maker's own unit shows.
- PCM 70 Owner's Manual, Software Version 3.00, p. 6-4: a register dump is sent on request, F0 06 00 <30 + channel> 61 <register 0-49> F7; register 50, the active program, is not asked for. The maker's own unit (software before 3.00) answers it, but with 30 ms after each answer it went quiet at a different register each read (6, 13, 28 of 50): 200 ms between an answer and the next request, and a missed request is asked again. Tried on two units with software before 3.00, 2026-10-23 ( B1): both answered all 50 requests, each with a 343-byte register dump, and one's names were imported.
- The operator's own Send Registers backup, 2026-10-17: each stored register's 334 nibbles, high nibble first, give 167 bytes; bytes 3-16 are its name, 13 ASCII characters padded with spaces and a terminating 0 (operator: 13 visible characters at most, blanks included). Registers 0 and 10 read DOUBLE DELAY, as 0.0 and 1.0 show on the unit; an empty register's name bytes are all 0. Register 50 is the active program, not a stored register.
- Register request for register 0, F0 06 00 <30 + channel> 61 00 F7 (Owner's Manual 3.00, p. 6-4), on each channel: the unit answers on its own with a register dump, F0 06 00 <channel - 1> 00 02 4E ... F7. Tried on the maker's two units.
Gaps, and why
- The manual prints 0.5 as 'SPIM ECHOES', kept as printed.
Status
Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.
| Feature | Status |
|---|---|
| Recall | Confirmed: recalled on the maker's own unit, October 2026 |
| Factory names | Confirmed: 0.0 is 'Chorus' and there is no 1.9 on the maker's own unit, October 2026; all factory names checked on 1 November 2026 |
| Factory tags | To test |
| Back up | Confirmed: a Send Registers backup of the maker's own unit, October 2026 |
| Restore | Confirmed: a backup sent back to the maker's own unit, October 2026 |
| Names from a backup | Confirmed: a Send Registers backup of the maker's own unit names 0.0 and 1.0 DOUBLE DELAY, as the unit shows them, October 2026 |
| Read names from the hardware | Confirmed: two of the maker's own units (software before 3.00) answered all 50 register requests and one's names were imported, October 2026 |
| Rename on hardware | Confirmed: R0.0 renamed on the maker's own unit, which showed the new name, and Read names from hardware gave it back, October 2026 |
| Recognise | Confirmed: both of the maker's own units were found, each on its own MIDI channel, also on a port shared with a PCM91, 24 October 2026 |
| Follows its front panel | Confirmed: a register and a preset picked on the maker's own unit moved Patchmark's current patch, with no setting changed, 22 October 2026 |
Questions
Does Patchmark edit the PCM70's sounds?
Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. Sound controls you add on the Patch tab it turns from there and the DAW's lanes.
How many PCM70 patches does it know?
93 numbers, numbered as the unit shows them, row and column. 43 of them carry the maker's names.
Can it back up the PCM70?
Yes, over SysEx, checked on a unit: start a backup in Patchmark, then on the unit: the front-panel 'Send Registers' function.
Does it read the patch names from the PCM70?
Yes, checked on a unit: Library ▸ Read names from hardware… asks the PCM70 for its patches and reads their names.
Has it been checked on a real PCM70?
Yes. Recall: recalled on the maker's own unit, October 2026. Factory names: 0.0 is 'Chorus' and there is no 1.9 on the maker's own unit, October 2026; all factory names checked on 1 November 2026. Back up: a Send Registers backup of the maker's own unit, October 2026. Restore: a backup sent back to the maker's own unit, October 2026. Names from a backup: a Send Registers backup of the maker's own unit names 0.0 and 1.0 DOUBLE DELAY, as the unit shows them, October 2026. Read names from the hardware: two of the maker's own units (software before 3.00) answered all 50 register requests and one's names were imported, October 2026. Rename on hardware: R0.0 renamed on the maker's own unit, which showed the new name, and Read names from hardware gave it back, October 2026. Recognise: both of the maker's own units were found, each on its own MIDI channel, also on a port shared with a PCM91, 24 October 2026. Follows its front panel: a register and a preset picked on the maker's own unit moved Patchmark's current patch, with no setting changed, 22 October 2026.
Which DAWs does it work in with the PCM70?
Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.
For beta testers
If you own a Lexicon PCM70, these checks help most (Beta testing):
- Rename a patch in the registers R0.0–R4.9 (the presets stay as they are) answering Rename on hardware: does the unit show the new name after a power cycle? Was the backup there?
- Which software version does it show when it starts?
- Do a register (R0.0–R4.9) and a preset (P0.0–P6.6) both recall?
- Is OMNI on?
Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.
This manual is for version 0.9.7.