Manual contents
For version 0.9.7 · beta · Change
You're reading the manual for Patchmark 0.9.7. Go to this page for 0.9.9
Lexicon PCM90
| Question | Answer |
|---|---|
| Does Patchmark work with the PCM90? | Documented, untested |
| Reads its patch names, from the unit or a backup? | Documented, untested |
| Backs it up over SysEx? | Documented, untested |
| Edits its parameters? | No |
Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Lexicon PCM90's patches inside your DAW project (350 numbers in 7 banks, 250 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. Patchmark can also back the unit up over SysEx, read its patch names from it and recognise it when asked who it is, following the maker's documentation; this is not yet checked on a unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.
The unit files its 250 presets in banks P0–P4 and your effects in the register banks R0 and R1, 50 each, numbered 0.0–4.9 as it shows them; Bank Select (CC 32) picks the bank and a Program Change the effect.
Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.
The Lexicon PCM90 template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.
What Patchmark does with it
- Recall: 50 patches in each of 7 banks (P0, P1, P2, P3, P4, R0, R1), numbered as the unit shows them, row and column. Patchmark sends Bank Select LSB (CC 32), then Program Change, on MIDI channel 1 to start with.
- Factory names: 250 patches in 5 of the 7 banks carry the maker's own names.
- Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
- Back up and restore: start a backup in Patchmark, then on the unit: Control 3.8 MIDI Dump: choose Bank R0-R1 with ADJUST, then press Store. (SysEx backup and restore)
- Names from a backup: Names… on a backup reads the patch names out of it.
- Read names from the hardware: Library ▸ Read names from hardware… asks the unit for its patches and reads their names, no backup needed: R0 and R1, all or one.
- Rename on hardware: after you rename a patch in the R0 and R1 banks, Patchmark can write the new name into the unit's memory too, and keep a backup first (taken from the maker's manual, not yet tried on a unit). (Renaming a patch)
- Recognise: the unit answers when asked who it is, and Device setup offers this template.
- Follows its front panel: choosing a patch on the unit moves the current patch in the list; on the unit, Control 3.4 Automation must be On, since the unit sends no Program Change when an effect is loaded on it, only a SysEx message that says which (When you change the patch on the device).
- Names on the unit: the unit shows patch names; renaming a patch here renames it in Patchmark, and in the R0 and R1 banks it can rename it on the unit too (above).
Connecting it
- Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
- The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
- For a backup, or reading names: Control 3.7 SysEx must be Receive On (the default).
- To follow the unit's front panel: Control 3.4 Automation must be On, since the unit sends no Program Change when an effect is loaded on it, only a SysEx message that says which.
- Insert the plugin as an audio effect on any track; the audio passes through untouched.
Sound controls
No list comes with the PCM90: add its controls on the Patch tab with Add control… (Sound controls).
On the PCM 90, the Patch row of each program's Edit matrix sets which CC moves which parameter. Add the same CCs here with Add control, or Learn them.
The Patch tab reaches only what the PCM90 maps to a CC or NRPN, not the parameters it edits over SysEx alone (What sound controls can reach).
Sources
- Lexicon PCM 90 Digital Reverberator User Guide, P/N 070-10399 Rev 1 (1997): p. 2-12 and 5-6 Control 3.3 Pgm Change (On: Program Change 0-49 = effects 0.0-4.9 in the current bank, 50-127 ignored) and the bank table (CC 32: 0-4 preset banks P0-P4, 5-6 register banks R0-R1); p. 2-15 setup defaults (Pgm Change On; receive OMNI, transmit channel 1); PCM 90 MIDI Implementation Details, P/N 070-11485 (1996), p. 3 (CC 32 selects the bank, CC 0 is ignored) and p. 35 (Appendix C). Every factory name checked, number by number, against the PCM 90 Presets sheet Rev 1. Card and algorithm-card banks (7 and up) are left out. Numbering 0.0-4.9 in each bank, as the unit shows it; factory preset names from the PCM 90 Presets sheet, P/N 070-11257 Rev 1, and User Guide chapter 4, pp. 4-2 to 4-27 (a trailing colon printed after some P2 names is taken as typesetting and left out; 'Spatial Plate' and 'Dlys/HallsBPM' are printed with 13 characters, one more than the unit's 12, MIDI Implementation p. 8, so the unit's own copy is shorter). Tags: the PCM91's, slot for slot: banks P0-P4 hold the same 250 presets in the same places (PCM 90 Presets sheet; PCM 91 User Guide chapter 4), so a tag means the same on both. Unconfirmed: no PCM90 has been checked.
- PCM 90 User Guide Rev 1, p. 2-17 and the Quick Reference Guide P/N 070-11256 Rev 1, p. 1: the display shows the bank, the location and the program name (12 characters, MIDI Implementation Details p. 8)
- PCM 90 User Guide Rev 1: p. 2-14 and 5-8 Control 3.8 MIDI Dump (current program, register banks R0-R1, card banks, maps, chains, setups; not the preset banks P0-P4); Control 3.7 SysEx must be Receive On, its factory setting (p. 2-14, 2-15); Control 3.9 Dump Speed (p. 2-14), Slow by default. MIDI Implementation Details P/N 070-11485, p. 9: Bank Dump F0 06 08 <device> 01 <bank> <labels> <50 effects, each with its checksum> F7, 116,919 bytes, the length of the PCM91's own R0 dump in the PCM 90's format, which takes 37 s at full MIDI speed and longer at a slower Dump Speed, so a backup waits up to 10 minutes for it. A bank received takes the unit about 2 s to sort (p. 9), so a restore pauses 2 s between banks. Memory Protect is ignored while SysEx is received (p. 5).
- PCM 90 MIDI Implementation Details P/N 070-11485 (1996): p. 29, Data Request F0 06 08 <device ID> 7F <type> <five parameter bytes, unused ones 0> F7, type 1A Effect Info with the bank and the effect 0-49, answered with Effect Information (p. 23); device ID 127 reaches every PCM 90 with SysEx on (p. 4). No more than 3 messages every 20 ms (p. 5). Every bank can be asked, the bank as Bank Select numbers it, Appendix C: P0-P4 0-4, R0-R1 5-6. A request it can't fulfil, such as a bank that isn't there, is answered with the Failure Response F0 06 08 <device ID> 7C F7 (p. 28). Whether it answers for an empty register isn't documented: a register that doesn't answer is passed over, as the PCM91's are. The PCM91, the PCM 90's successor, answers the same request in about 20 ms on the maker's own unit. Unconfirmed: no PCM90 has been checked.
- PCM 90 MIDI Implementation Details P/N 070-11485, p. 9: Bank Dump F0 06 08 <device> 01 <bank>, the bank's label (7 bytes) and five row labels (11 each), then its 50 effects, 0.0 to 4.9, each followed by its checksum, from byte 69 counting F0 as 1, then F7, 116,919 bytes: 2,337 bytes an effect, its 1,168 bytes as 2,336 nibbles, low first (p. 10), and their 7-bit sum. Decoded, an effect's name is its bytes 5-16, 12 ASCII characters. The maker's own PCM91 sends its Bank Dumps in this format, product 08, and its R0 dump reads as its display shows it. R0 is bank 5 and R1 bank 6 (Appendix C); preset banks P0-P4 are never dumped (User Guide p. 5-8).
- PCM 90 MIDI Implementation Details P/N 070-11485, p. 20: Program Change Dump (15), F0 06 08 <device ID> 15 <bank> <program> F7, bidirectional, the message SysEx Automation sends a program change with; with Control 3.4 Automation On, "almost all changes made by front panel operations are transmitted as PCM 90 SysEx messages" (User Guide Rev 1 p. 5-7, p. 2-13). The MIDI chart says it never sends a Program Change (p. 5-9). The device ID is Automation's Target ID, All by default, so any is read. The bank as Bank Select numbers it, P0-P4 0-4, R0 5, R1 6 (Appendix C). The maker's own PCM91 sends this very message, product 08 and type 15, when an effect is loaded on it. Unconfirmed: no PCM90 has been checked.
- PCM 90 MIDI Implementation Details, P/N 070-11485, Appendix D p. 36: Device Inquiry reply F0 7E <device ID> 06 02 06 00 00 08 00 <major> <minor> <release> 00 F7 (Lexicon, family 00 00, member 08 00, the PCM 90). The Device Inquiry's channel byte is taken as the SysEx device ID (default 0, Control 3.7). Unconfirmed on a unit.
Gaps, and why
- Card banks and algorithm-card banks are not included.
- The guide gives OMNI as the receive channel's factory setting; the template starts on 1.
Status
Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.
| Feature | Status |
|---|---|
| Recall | To test |
| Factory names | To test |
| Factory tags | To test |
| Back up | To test |
| Restore | To test |
| Names from a backup | To test |
| Read names from the hardware | To test |
| Rename on hardware | To test |
| Recognise | To test |
| Follows its front panel | To test |
Questions
Does Patchmark edit the PCM90's sounds?
Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. Sound controls you add on the Patch tab it turns from there and the DAW's lanes.
How many PCM90 patches does it know?
350 numbers, in 7 banks, numbered as the unit shows them, row and column. 250 of them carry the maker's names.
Can it back up the PCM90?
Not yet checked on a unit. Following the maker's documentation, it backs the unit up over SysEx: start a backup in Patchmark, then on the unit: Control 3.8 MIDI Dump: choose Bank R0-R1 with ADJUST, then press Store.
Does it read the patch names from the PCM90?
Not yet checked on a unit. Following the maker's documentation, Library ▸ Read names from hardware… asks the PCM90 for its patches and reads their names.
Has it been checked on a real PCM90?
Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).
Which DAWs does it work in with the PCM90?
Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.
For beta testers
If you own a Lexicon PCM90, these checks help most (Beta testing):
- Rename a patch in the R0 and R1 banks answering Rename on hardware: does the unit show the new name after a power cycle? Was the backup there?
- Which software version?
- Does Recognise find it?
- Do a preset in P0 and a register in R0 both recall?
- With Control 3.4 Automation On, does loading an effect on the unit move Patchmark's current patch, in P0 and in R1?
- Does Read names from hardware fill R0, R1 and a preset bank with the names the unit shows?
- Does Names… on a Bank R0 dump show the register names?
- Are 'Spatial Plate' and 'Dlys/HallsBPM' spelled the same on your unit (the list prints 13 letters, the unit has 12)?
Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.
This manual is for version 0.9.7.