Sequential Prophet-6 Desktop
| Question | Answer |
|---|---|
| Does Patchmark work with the Prophet-6 Desktop? | Yes, checked on a unit |
| Reads its patch names, from the unit or a backup? | Yes, checked on a unit |
| Backs it up over SysEx? | Yes, checked on a unit |
| Edits its parameters? | No |
Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Sequential Prophet-6 Desktop's patches inside your DAW project (1000 numbers in 10 banks, 1000 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. Patchmark can also back the unit up over SysEx, read its patch names from it and recognise it when asked who it is, as checked on a unit. Recall is confirmed on a real unit: recalled on the maker's own unit, October 2026.
Readiness: Tested. Tried on our own units.
What Patchmark does with it
- Recall: 100 patches in each of 10 banks (0 User, 1 User, 2 User, 3 User, 4 User, 5 Factory, 6 Factory, 7 Factory, 8 Factory, 9 Factory), numbered by the hundred, bank and patch together, as the unit shows them (000–999). Patchmark sends Bank Select LSB (CC 32), then Program Change, on MIDI channel 1 to start with.
- Factory names: 1000 patches in 10 of the 10 banks carry the maker's own names.
- Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
- Back up and restore: start a backup in Patchmark, then on the unit: Globals, Pgm Dump: choose usr (all user banks) and send. (SysEx backup and restore)
- Names from a backup: Names… on a backup reads the patch names out of it.
- Read names from the hardware: Library ▸ Read names from hardware… asks the unit for its patches and reads their names, no backup needed: its 5 user banks, all or one.
- Rename on hardware: after you rename a patch in user banks 0–4, Patchmark can write the new name into the unit's memory too, and keep a backup first. (Renaming a patch)
- Recognise: the unit answers when asked who it is, and Device setup offers this template.
- Follows its front panel: choosing a patch on the unit moves the current patch in the list (When you change the patch on the device).
- Names on the unit: the unit shows numbers only, so the names you see are Patchmark's; in user banks 0–4 a new name can still be written into the unit's memory (above).
Connecting it
- Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
- The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
- For a backup, or reading names: Globals ▸ MIDI SysEx must name the port in use (MIDI or USB).
- Insert the plugin as an audio effect on any track; the audio passes through untouched.
Sound controls
The Patch tab turns 68 of the Prophet-6 Desktop's sound controls, in the Oscillators, Glide, Filter, VCA Env, Filter Envelope, LFO, Effects, Voice and Arpeggiator sections, and puts any on a DAW lane (Sound controls).
On the Prophet-6, Globals: Param Rcv set to NRPN.
Values on the Patch tab
Of its 68 controls, 67 show their values as the Prophet-6 Desktop's manual gives them (units, names, %), 1 follow a guess.
Guessed, not given by the manuals: if you own a Prophet-6 Desktop, check these against the unit's display and tell us what it shows (Beta testing):
- FX 1 Type: that its 0-5 are the first six types of the manual's list.
Sources
- Sequential Prophet-6 Operation Manual, Version 2.1 (Feb 2021), covering the keyboard and the desktop module: p. 2 'Sound Banks' (1000 programs, 10 banks of 100; banks 0-4 user, 5-9 factory and permanent); Appendix C p. 73-75 'Received Channel Messages' (Program Change 0-99 within the current bank; Bank Select on CC 32, values 0-9). p. 3 and p. 56: Program Change is received only while Preset (program mode) is on. The factory MIDI channel is not documented. Numbering 000-999 as the unit shows it; factory names from the Prophet-6 Factory Presets list (June 2015), banks 5-9 identical to banks 0-4 as shipped (Operation Manual p. 2). User banks 0-4 can be overwritten on the unit; a name you give in the plugin always wins. Tags: programs 411-458, the Prophet-5 presets 1-1 to 5-8, from the original Prophet-5 factory patch sheets (Sequential Circuits, scanned at midi.org); the others from the program's name, many a best guess, since Sequential publishes no categories.
- Prophet-6 Operation Manual, Appendix C: Program Parameter Data pp. 88-90 (PDF pages); Param Rcv p. 87 (NRPN 1030) Values as the unit shows them: switches Off/On; Osc Freq in semitones over five octaves, shown as notes C0-C5; Fine and the amounts 0-254 centred on 127; names from the manual's Glide, Filters (Keyboard Off/Half/Full), Key Assign Modes, LFO, Effects (Type list; FX 1's 0-5 taken as its first six) and Arpeggiator (Mode, Octave, Value) sections; the rest 0-100 %.
- Prophet-6 Operation Manual v2.1 (2021): p. 2 'Selecting Programs' and p. 4, the main display shows bank and program numbers only; names are kept in the program (p. 80, NRPN 236-255) but never shown on the unit
- Prophet-6 Operation Manual 2.1 (Feb 2021): p. 16-17 Global Settings 'Pgm Dump' (Prg, Ten, Ban, usr, All) and p. 62 'Exporting Programs and Banks'; p. 83 Program Data Dump F0 01 2D 02 <bank 0-9> <program 0-99> <1171 bytes packed MS bit> F7 (1178 bytes); p. 14 and p. 86 Global 'MIDI SysEx' must name the port in use (MIDI or USB). Programs load back into the same bank and program (p. 17, p. 62).
- Prophet-6 Operation Manual 2.1 (Feb 2021), p. 81: Request Program Dump F0 01 2D 05 <bank 0-9> <program 0-99> F7, answered with a Program Data Dump (p. 82). Banks 0-4 are the user banks, 5-9 the factory ones. The Global MIDI SysEx setting must name the port in use (p. 84). No pause between requests is documented; each waits for its reply.
- Prophet-6 Operation Manual 2.1, pp. 82-83: Program Data Dump F0 01 2D 02 <bank> <program> <1171 bytes packed seven in eight, the first byte of each group holding the others' top bits, the first one's in bit 0>. The name is 20 ASCII characters at unpacked byte 107, padded with spaces: the manual's parameter table (Name, NRPN 236-255, p. 79) doesn't give dump offsets, so 107 comes from real dumps (the 500 factory programs) and the KnobKraft librarian's Prophet-6 adaptation. To confirm on the maker's own unit.
- Prophet-6 (keyboard) Operation Manual v2.1, Appendix C, Universal System Exclusive Message (Device Inquiry), p. 81: F0 7E <channel> 06 02 01 2D 01 00 00 <version> F7. The Desktop's own manual was not found; that the Desktop replies the same is to be confirmed on the unit.
Gaps, and why
- None known.
Status
Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.
| Feature | Status |
|---|---|
| Recall | Confirmed: recalled on the maker's own unit, October 2026 |
| Factory names | Confirmed: the factory names shown on the maker's own unit, 1 November 2026 |
| Factory tags | To test |
| Back up | Confirmed: backed up from the maker's own unit, October 2026, and again on 1 November 2026 |
| Restore | Confirmed: a backup sent back to the maker's own unit, October 2026, and again on 1 November 2026 |
| Names from a backup | Confirmed: a backup of the maker's own unit, read as Names… reads it, gives the names it shows, 1 November 2026 |
| Read names from the hardware | Confirmed: a user bank read from the maker's own unit gave the names it holds, on the right numbers, 22 October 2026 |
| Rename on hardware | Confirmed: a renamed patch showed its new name on the maker's own unit, 11 October 2026 |
| Recognise | Confirmed: the maker's own unit answered and Device setup offered this template, 23 October 2026 |
| Follows its front panel | Confirmed: a program picked on the maker's own unit, in bank 0 and then in bank 5, moved Patchmark's current patch, 22 October 2026 |
Questions
Does Patchmark edit the Prophet-6 Desktop's sounds?
Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. It turns the Prophet-6 Desktop's sound controls from the Patch tab and the DAW's lanes, over MIDI.
How many Prophet-6 Desktop patches does it know?
1000 numbers, in 10 banks, numbered by the hundred, bank and patch together, as the unit shows them (000–999). 1000 of them carry the maker's names.
Can it back up the Prophet-6 Desktop?
Yes, over SysEx, checked on a unit: start a backup in Patchmark, then on the unit: Globals, Pgm Dump: choose usr (all user banks) and send.
Does it read the patch names from the Prophet-6 Desktop?
Yes, checked on a unit: Library ▸ Read names from hardware… asks the Prophet-6 Desktop for its patches and reads their names.
Has it been checked on a real Prophet-6 Desktop?
Yes. Recall: recalled on the maker's own unit, October 2026. Factory names: the factory names shown on the maker's own unit, 1 November 2026. Back up: backed up from the maker's own unit, October 2026, and again on 1 November 2026. Restore: a backup sent back to the maker's own unit, October 2026, and again on 1 November 2026. Names from a backup: a backup of the maker's own unit, read as Names… reads it, gives the names it shows, 1 November 2026. Read names from the hardware: a user bank read from the maker's own unit gave the names it holds, on the right numbers, 22 October 2026. Rename on hardware: a renamed patch showed its new name on the maker's own unit, 11 October 2026. Recognise: the maker's own unit answered and Device setup offered this template, 23 October 2026. Follows its front panel: a program picked on the maker's own unit, in bank 0 and then in bank 5, moved Patchmark's current patch, 22 October 2026.
Which DAWs does it work in with the Prophet-6 Desktop?
Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.
For beta testers
If you own a Sequential Prophet-6 Desktop, these checks help most (Beta testing):
- Rename a patch in user banks 0–4 answering Rename on hardware: does Read names from hardware give the new name after a power cycle? Was the backup there?
- Which OS version?
- Do banks 0 and 5 both recall? Were your user banks 0–4 still yours afterwards?
- Do the guessed values under Values on the Patch tab match what the unit shows?
Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.
This manual is for version 0.9.7.