Patchmark‹ All plug-ins
Manual contents
For version 0.9.7 · beta · Change

You're reading the manual for Patchmark 0.9.7. Go to this page for 0.9.9

Devices

Lexicon PCM80

Question Answer
Does Patchmark work with the PCM80? Documented, untested
Reads its patch names, from the unit or a backup? Documented, untested
Backs it up over SysEx? Documented, untested
Edits its parameters? No

Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Lexicon PCM80's patches inside your DAW project (250 numbers in 5 banks, 200 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. Patchmark can also back the unit up over SysEx, read its patch names from it and recognise it when asked who it is, following the maker's documentation; this is not yet checked on a unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.

The unit files its 200 presets in banks P0–P3 and your effects in the Register bank R, 50 each, numbered 0.0–4.9 as it shows them; Bank Select (CC 32) picks the bank and a Program Change the effect.

Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.

The Lexicon PCM80 template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.

What Patchmark does with it

  • Recall: 50 patches in each of 5 banks (R, P0, P1, P2, P3), numbered as the unit shows them, row and column. Patchmark sends Bank Select LSB (CC 32), then Program Change, on MIDI channel 1 to start with.
  • Factory names: 200 patches in P0, P1, P2, P3 carry the maker's own names.
  • Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
  • Back up and restore: start a backup in Patchmark, then on the unit: Control 3.8 Dump: choose CurrentPgm or Bank R with ADJUST, then press Store. (SysEx backup and restore)
  • Names from a backup: Names… on a backup reads the patch names out of it.
  • Read names from the hardware: Library ▸ Read names from hardware… asks the unit for its patches and reads their names, no backup needed: its one bank, R.
  • Rename on hardware: after you rename a patch in the R bank, Patchmark can write the new name into the unit's memory too, and keep a backup first (taken from the maker's manual, not yet tried on a unit). (Renaming a patch)
  • Recognise: the unit answers when asked who it is, and Device setup offers this template.
  • Follows its front panel: choosing a patch on the unit moves the current patch in the list; on the unit, Control 3.4 Automation must be On, since the unit sends no Program Change when an effect is loaded on it, only a SysEx message that says which (When you change the patch on the device).
  • Names on the unit: the unit shows patch names; renaming a patch here renames it in Patchmark, and in the R bank it can rename it on the unit too (above).

Connecting it

  • Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
  • The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
  • For a backup, or reading names: Control 3.7 SysEx must be On (the default).
  • To follow the unit's front panel: Control 3.4 Automation must be On, since the unit sends no Program Change when an effect is loaded on it, only a SysEx message that says which.
  • Insert the plugin as an audio effect on any track; the audio passes through untouched.

Sound controls

No list comes with the PCM80: add its controls on the Patch tab with Add control… (Sound controls).

On the PCM 80, the Patch row of each program's Edit matrix sets which CC moves which parameter. Add the same CCs here with Add control, or Learn them.

The Patch tab reaches only what the PCM80 maps to a CC or NRPN, not the parameters it edits over SysEx alone (What sound controls can reach).

Sources

  • Lexicon PCM 80 Digital Effects Processor User Guide 070-11263 Rev 1 (1997): p. 2-13 and p. 5-6 Control 3.3 Pgm Change and the bank table (CC 32: 0-3 preset banks P0-P3, 4 the Register bank R); p. 2-15 setup defaults; p. 2-17 and p. 4-1, 200 presets in P0-P3 and 50 registers, 0.0-4.9; pp. 4-2 to 4-21 the presets. Program Change 0-49 = effects 0.0-4.9 in the current bank, 50-127 ignored, with Control 3.3 Pgm Change On (the default); CC 32 selects the bank and CC 0 is ignored (PCM 80 MIDI Implementation Details 070-11486, p. 3 and p. 37); the 1994 edition (070-10820) and the guide's patch sources (p. 2-31) reserve both, so CC 32 alone works under either. Numbering 0.0-4.9 in each bank, as the unit shows it. The setup table gives OMNI as the receive default and the MIDI chart 1; 1 is used. Card banks are left out. Factory names from chapter 4's preset headers, spelled as the guide's index spells them where the two differ: the index names fit the unit's 12 characters (p. 2-26), four header names don't. Tags: from each preset's category in the guide (a modulation, echo, ambience, EQ, gain, resonant chord or remix effect; a reverb or processed reverb), plus what its name says: a chorus or detune, a flange, an echo or slap, a rotary, tremolo or pan, a pitch shift or chord, a filter, a freeze; a reverb by its space (a name with none is Hall, Slope Down Gated); Vocal, Drums and Guitar by name. The guides don't print each preset's algorithm, so the tags read the names. Unconfirmed: no PCM80 has been checked.
  • PCM 80 User Guide p. 1-2 and p. 2-17: two rows of 20 characters, the lower one the bank, location and program name
  • PCM 80 V1.10 MIDI Implementation Details 070-11486: p. 2 (nibbles, pacing), p. 4 (F0 06 07, Lexicon 06, PCM 80 product 07), p. 6 (dumps). The front panel's dumps: Control 3.8 (PCM 80 User Guide p. 5-8). Control 3.7 SysEx must be On (the default; Device ID 0). A dump sent back to the unit is kept as received.
  • PCM 80 MIDI Implementation Details 070-10820: Data Request F0 06 07 <device ID> 7F <type> <five parameter bytes, unused ones 0> F7, type 1A Program Info with the bank and the program 0-49, answered with Effect Information (1A); device ID 127 reaches every PCM 80 with SysEx on (PCM 80 V1.10 MIDI Implementation Details 070-11486, p. 4), so the unit's own ID needn't be known. Every bank can be asked: P0-P3 0-3 and R 4, as the document and Bank Select number them. No more than 3 messages every 20 ms (V1.10 p. 2). Whether it answers for an empty register isn't documented: a register that doesn't answer is passed over, as the PCM91's are. The PCM91, the PCM 90's twin of the same years, answers the same request in about 20 ms on the maker's own unit. Unconfirmed: no PCM80 has been checked.
  • PCM 80 V1.10 MIDI Implementation Details 070-11486: p. 6, Single Effect Dump F0 06 07 <device ID> 02 <bank> <program> <1412 bytes, each byte of the effect sent as two, low nibble first> <checksum> F7; p. 7, the effect's bytes 4-15 are its name, 12 ASCII characters padded with spaces (p. 2). A bank dump (01) packs 50 effects in one message and isn't read for names.
  • PCM 80 MIDI Implementation Details 070-10820: Program Change (15), F0 06 07 <device ID> 15 <bank> <program> F7, bidirectional, "used in SysEx automation to effect Program change"; with Control 3.4 Automation On "all changes made by front panel operations are transmitted as PCM 80 SysEx messages" and "Program Changes are sent directly via SysEx" (PCM 80 User Guide p. 5-7). The MIDI chart says it never sends a Program Change (p. 5-9). The device ID is Automation's Target ID, All by default, so any is read. The bank as the document numbers it, the same as Bank Select: P0-P3 0-3, R 4. The PCM91 sends the same message, with the PCM 90's product number 08, when an effect is loaded on the maker's own unit. Unconfirmed: no PCM80 has been checked.
  • PCM 80 V1.10 MIDI Implementation Details 070-11486, p. 38: the Device Inquiry is answered with F0 7E <device ID> 06 02 06 00 00 07 00 <version> F7

Gaps, and why

  • Names… on a backup reads a dump of one effect, if the unit numbers it with its bank and register: what a CurrentPgm dump carries in those bytes isn't documented. A Bank R dump packs 50 effects in one message and isn't read for names: use Read names from hardware for the whole bank.
  • Memory-card and algorithm-card banks are not included.
  • The guide gives OMNI as the receive channel's factory setting and its MIDI chart 1; the template starts on 1.

Status

Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.

Feature Status
Recall To test
Factory names To test
Factory tags To test
Back up To test
Restore To test
Names from a backup To test
Read names from the hardware To test
Rename on hardware To test
Recognise To test
Follows its front panel To test

Questions

Does Patchmark edit the PCM80's sounds?

Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. Sound controls you add on the Patch tab it turns from there and the DAW's lanes.

How many PCM80 patches does it know?

250 numbers, in 5 banks (R, P0, P1, P2, P3), numbered as the unit shows them, row and column. 200 of them carry the maker's names.

Can it back up the PCM80?

Not yet checked on a unit. Following the maker's documentation, it backs the unit up over SysEx: start a backup in Patchmark, then on the unit: Control 3.8 Dump: choose CurrentPgm or Bank R with ADJUST, then press Store.

Does it read the patch names from the PCM80?

Not yet checked on a unit. Following the maker's documentation, Library ▸ Read names from hardware… asks the PCM80 for its patches and reads their names.

Has it been checked on a real PCM80?

Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).

Which DAWs does it work in with the PCM80?

Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.

For beta testers

If you own a Lexicon PCM80, these checks help most (Beta testing):

  • Rename a patch in the R bank answering Rename on hardware: does the unit show the new name after a power cycle? Was the backup there?
  • Do a preset in P0 and a register in R both recall?
  • With Control 3.4 Automation On, does loading an effect on the unit move Patchmark's current patch, in P0 and in R?
  • Does Read names from hardware fill the Register bank, and a preset bank with the names the unit shows?
  • What does Recognise show?
  • Does the display spell Detune&Room, Wizz & Wazz and the Freez presets as the template does?

Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.

This manual is for version 0.9.7.