Manual contents
For version 0.9.7 · beta · Change
You're reading the manual for Patchmark 0.9.7. Go to this page for 0.9.9
Lexicon MPX550
| Question | Answer |
|---|---|
| Does Patchmark work with the MPX550? | Documented, untested |
| Reads its patch names, from the unit or a backup? | No |
| Backs it up over SysEx? | Documented, untested |
| Edits its parameters? | No |
Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Lexicon MPX550's patches inside your DAW project (319 numbers in 28 banks, 255 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. Patchmark can also back the unit up over SysEx, following the maker's documentation; this is not yet checked on a unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.
The unit files its 255 presets in 27 banks, Plate to Live-FOH, plus a User bank of 64; the template reaches each bank with Bank Select (CC 32) and its programs with a Program Change, the first program on 001, and backs up the User programs from the unit's own MIDI dump.
Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.
The Lexicon MPX550 template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.
What Patchmark does with it
- Recall: 319 patches in 28 banks (Plate, Gate/Inv, Hall, Chamber, Ambience, Room, Tremolo, Rotary, Chorus, Flange, Detune, Pitch, Dly/Eko, Special FX, Flng-Dly, Pch-Dly, Chor-Dly, Dly-Rvb, Flng-Rvb, Pch-Rvb, Chor-Rvb, MSplit Dly, MSplit Rvb, Dual Mono, Cmprssr, Dynamics, Live-FOH, User), from 1 to 64 in a bank, numbered 001–064. Patchmark sends Bank Select LSB (CC 32), then Program Change, on MIDI channel 1 to start with.
- Factory names: 255 patches in 27 of the 28 banks carry the maker's own names.
- Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
- Back up and restore: start a backup in Patchmark, then on the unit: Press System, turn EDIT knob 1 to Dump User Bank and EDIT knob 3 to 1-16, press Store; then 17-32, 33-48 and 49-64 the same way, each within 30 seconds of the last. (SysEx backup and restore)
- Names on the unit: the unit shows patch names, so renaming a patch here renames it in Patchmark only, and Patchmark says so the first time (Renaming a patch).
Connecting it
- Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
- The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
- For a backup, or reading names: keep System Mode's MIDI Out/Thru on Out, the factory setting, so the dump leaves by the MIDI OUT/THRU jack.
- Insert the plugin as an audio effect on any track; the audio passes through untouched.
Sound controls
No list comes with the MPX550: add its controls on the Patch tab with Add control… (Sound controls).
On the MPX550, Learn mode gives a front-panel knob or button its CC. Add the same CCs here with Add control, or Learn them.
The Patch tab reaches only what the MPX550 maps to a CC or NRPN, not the parameters it edits over SysEx alone (What sound controls can reach).
Sources
- Lexicon MPX 550 User Guide 070-14912 Rev 1 (2002): pp. 1-2 to 1-3, 255 presets in 27 banks and a User bank; p. 2-4, 64 User locations, empty when shipped; p. 3-3, MIDI channel 1 and MIDI Program Change Enabled by default; p. 6-3, CC 32 picks the bank (0 Plate to 26 Live-FOH, 27 User) and a Program Change a program in it, 'to load all 255 presets and 64 user programs'. The examples on p. 6-3 count a bank's programs from 1, and the MIDI chart p. 6-9 reads '0 to 15 = 1 to 16': the template takes Program Change 0 as the bank's first program. The chart's 16-program limit, copied from the MPX 110, contradicts the 64 User programs; the template follows p. 6-3. A bank holds 1 to 20 presets: the patches run to 64 in each bank, and those past a bank's last program recall nothing, so each factory bank leaves them out. Factory names from chapter 4, pp. 4-2 to 4-37, as printed, with the manual's spacing; preset 249's name isn't printed, and the text calls it the Dynamics preset (p. 4-32). The User bank is yours, so it has no names here. Factory names checked against the printed guide (manuals repo): all 255 match. Backup: System Mode's Dump User Bank (press System, turn EDIT knob 1 to it and EDIT knob 3 to the group 1-16, 17-32, 33-48 or 49-64, press Store; pp. 3-8 and 6-6 to 6-7) sends 16 User programs at a time out of MIDI OUT/THRU set to Out. The MIDI chart (pp. 6-8 to 6-9) sends and recognises Lexicon SysEx (product ID 22 decimal, device ID the MIDI channel), and sends no Program Change and no universal SysEx: the unit can't say which program was chosen on it or who it is. Tags: as the MPX200's, program for program, the Special FX one by one (a ducker is Dynamics, Stereo Stage Utility); a compressor is Dynamics, with its reverb's space when it has one (p. 4-31), and a Live-FOH program its two effects, a reverb without a size as Hall. Lexicon's MPX Series MIDI Implementation, User Guide Addendum 070-14979 Rev 1 (09/02), pp. 4-6 and the MPX 550 tables pp. 44-56, documents parameter Query and Data messages only (product ID 16 hex): no program dump format, no dump request and no name position, so a dump is kept as received; its dump events aren't explained, and two of them clear the unit's memory, so Patchmark never sends them. Unconfirmed: no unit has been checked.
- MPX 550 User Guide pp. 1-6 to 1-7: a graphic LCD shows the program's number and name and its bank
- MPX 550 User Guide pp. 3-8 and 6-6 to 6-7: Dump User Bank sends the User programs in groups of 16 when Store is pressed, and a group sent back returns to its own User locations; the MIDI chart pp. 6-8 to 6-9: Lexicon SysEx sent and recognised. Their format isn't documented: a dump is kept as received and sent back as it came.
Gaps, and why
- Names from a backup: Lexicon doesn't document the dump's format, so there is nowhere known to read the names from.
- Read names from the hardware: its MIDI chart and Lexicon's MPX Series MIDI Implementation document no request for a program or its name.
- Recognise: its MIDI chart says it sends no universal SysEx, so it can't answer being asked who it is.
- Follows its front panel: its MIDI chart says it sends no Program Change, so choosing a program on it can't be followed.
- The MIDI chart allows Program Changes for 16 programs a bank only, which would leave User programs 17–64 out of reach; the template follows the guide's text, which says every preset and User program can be loaded.
- A backup is kept as received: Lexicon doesn't document the dump's format. Sending it back is how the guide expects a sequencer to restore one; each group of 16 returns to its own User locations.
- Preset 249's name isn't printed; the template calls it Dynamics, as the guide's text does.
Status
Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.
| Feature | Status |
|---|---|
| Recall | To test |
| Factory names | To test |
| Factory tags | To test |
| Back up | To test |
| Restore | To test |
Questions
Does Patchmark edit the MPX550's sounds?
Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. Sound controls you add on the Patch tab it turns from there and the DAW's lanes.
How many MPX550 patches does it know?
319 numbers, in 28 banks, numbered 001–064. 255 of them carry the maker's names.
Can it back up the MPX550?
Not yet checked on a unit. Following the maker's documentation, it backs the unit up over SysEx: start a backup in Patchmark, then on the unit: Press System, turn EDIT knob 1 to Dump User Bank and EDIT knob 3 to 1-16, press Store; then 17-32, 33-48 and 49-64 the same way, each within 30 seconds of the last.
Does it read the patch names from the MPX550?
Not yet: its MIDI chart and Lexicon's MPX Series MIDI Implementation document no request for a program or its name.
Has it been checked on a real MPX550?
Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).
Which DAWs does it work in with the MPX550?
Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.
For beta testers
If you own a Lexicon MPX550, these checks help most (Beta testing):
- Do User programs 17–64 recall, and MSplit Rvb's 17–20?
- Start a backup, then on the unit: System, EDIT knob 1 to Dump User Bank, EDIT knob 3 to 1-16, Store; then 17-32, 33-48 and 49-64. Is one backup saved with all four groups? After changing a User program, does restoring it bring the program back?
- Does the display spell the names as the list does (the manual sets some with spaces, such as Flng + Tap)?
- Send us a Dump User Bank backup, with the names of your first few User programs as the unit shows them: it shows where a backup keeps the names. (How and where)
Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.
This manual is for version 0.9.7.