| Question | Answer |
|---|---|
| Does Patchmark work with the PCM91? | Yes, checked on a unit |
| Reads its patch names, from the unit or a backup? | Yes, checked on a unit |
| Backs it up over SysEx? | Yes, checked on a unit |
| Edits its parameters? | No |
Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Lexicon PCM91's patches inside your DAW project (550 numbers in 11 banks, 450 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. Patchmark can also back the unit up over SysEx, read its patch names from it and recognise it when asked who it is, as checked on a unit. Recall is confirmed on a real unit: recalled on the maker's own unit, October 2026.
Readiness: Tested. Tried on our own units.
What Patchmark does with it
- Recall: 50 patches in each of 11 banks (P0, P1, P2, P3, P4, P5, P6, P7, P8, R0, R1), numbered as the unit shows them, row and column. Patchmark sends Bank Select LSB (CC 32), then Program Change, on MIDI channel 1 to start with.
- Factory names: 450 patches in 9 of the 11 banks carry the maker's own names.
- Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
- Back up and restore: start a backup in Patchmark, then on the unit: Control 3.8 MIDI Dump: choose Bank R0 or R1 with ADJUST, then press Store. (SysEx backup and restore)
- Names from a backup: Names… on a backup reads the patch names out of it.
- Read names from the hardware: Library ▸ Read names from hardware… asks the unit for its patches and reads their names, no backup needed: R0 and R1, all or one.
- Rename on hardware: after you rename a patch in the R0 and R1 banks, Patchmark can write the new name into the unit's memory too, and keep a backup first. (Renaming a patch)
- Recognise: the unit answers when asked who it is, and Device setup offers this template.
- Follows its front panel: choosing a patch on the unit moves the current patch in the list; on the unit, Control 3.4 Automation must be On, since the unit sends no Program Change when an effect is loaded on it, only a SysEx message that says which (When you change the patch on the device).
- Names on the unit: the unit shows patch names; renaming a patch here renames it in Patchmark, and in the R0 and R1 banks it can rename it on the unit too (above).
Connecting it
- Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
- The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
- For a backup, or reading names: Control 3.7 SysEx must be Receive On, and the Device ID must match.
- To follow the unit's front panel: Control 3.4 Automation must be On, since the unit sends no Program Change when an effect is loaded on it, only a SysEx message that says which.
- Insert the plugin as an audio effect on any track; the audio passes through untouched.
Sound controls
No list comes with the PCM91: add its controls on the Patch tab with Add control… (Sound controls).
On the PCM 91, the Patch row of each program's Edit matrix sets which CC moves which parameter. Add the same CCs here with Add control, or Learn them.
The Patch tab reaches only what the PCM91 maps to a CC or NRPN, not the parameters it edits over SysEx alone (What sound controls can reach).
Sources
- Lexicon PCM 91 Digital Reverberator User Guide, P/N 070-12662 Rev 1 (09/01): p. 2-13 Control 3.3 Pgm Change (On: Program Change 0-49 = effects 0.0-4.9 in the current bank) and the bank table (CC 32: 0-8 preset banks P0-P8, 9-10 register banks R0-R1); p. 2-15 defaults (Pgm Change On; receive Omni, transmit channel 1); p. 4-2 bank layout; p. 5-8 MIDI Implementation Chart (basic channel 1). Card banks are left out: the guide's two bank tables disagree on them (p. 2-13, p. 5-6). Numbering 0.0-4.9 in each bank, as the unit shows it; factory preset names from Chapter 4, pp. 4-3 to 4-52 (a trailing colon printed after ten P2 names is taken as typesetting and left out, and the typeset apostrophes in four names are the unit's ASCII one). Tags: from the PCM 91 Preset Menu (Lexicon): each bank's category (P0 Halls, P1 Rooms, P2 Plates, P3/P7 Post, P4 Splits, P5 Studio, P6 Live, P8 Surround), its row headings and each preset's description; a preset whose description says it is another space (a gated room in the Halls bank) is tagged as described.
- PCM 91 User Guide, Rev 1 (070-12662): p. 1-4 'Front Panel Overview', item 3, two rows of 20 characters display effect names
- Dump time: the maker's Bank R0 dump, captured on 2026-10-17, is one SysEx message of 116,919 bytes, which takes 37 s at full MIDI speed and longer at a slower Control 3.9 Dump Speed, by an amount the guide doesn't give (p. 2-15), so a backup waits up to 10 minutes for it. PCM 91 User Guide P/N 070-12662 Rev 1 (09/01): p. 2-14 and p. 5-8 Bulk Data Dumps (Current Pgm, Bank R0-R1, card banks, maps, chains, setups); p. 5-8 and 5-9 MIDI Implementation Chart, Lexicon manufacturer ID 6; Control 3.7 SysEx must be Receive On and the Device ID must match (p. 2-14, 5-6, 5-7); Control 3.9 Dump Speed (p. 2-15). The dump format is in 'PCM 91 MIDI Implementation Details', available only from Lexicon (p. 5-8), so a dump is kept as received; the names in a register bank's dump are read from the maker's own unit's dump.
- Found on a PCM91, 22 October 2026: F0 06 11 <device ID 0> 7F 1A <bank> <effect 0-49> 00 00 00 F7, product 11 as its Recognise reply names it; it answers in about 20 ms. The bank is numbered as Bank Select (CC 32) numbers it, P0-P8 0-8 and R0 9, checked on P0, P5 and R0; R1 is taken as 10, the next number, unchecked. The effect is row x 10 + column, 1.1 being 11. It answers no request with the PCM90's product number 08. No more than 3 messages every 20 ms, as the PCM90 asks (PCM 90 MIDI Implementation Details P/N 070-11485, p. 2). It sends nothing for an empty register (seen on a PCM91's R0, 23 October 2026), so a read goes on past one; 300 ms is fifteen times its answer, which keeps an R0 with 35 empty registers to about 20 seconds.
- A Bank Dump of R0 from the maker's own PCM91, October 2026: one message F0 06 08 <device> 01 <bank>, the PCM90's product number and Bank Dump (PCM 90 MIDI Implementation Details P/N 070-11485, p. 6), 62 bytes of labels, then the bank's 50 effects in order, 0.0 to 4.9, each 2,337 bytes, from byte 68. Each effect is what the PCM90's Single Effect Dump carries (p. 7): its 1,168 bytes as 2,336 nibbles, low first, then the low 7 bits of their sum, which fits all 50 effects of the dump. Decoded, bytes 0-1 are 1168, low first, and the name is 12 ASCII characters at bytes 5-16, as in the PCM90's (p. 8); an empty register is all zeros. The bank is 5 for R0, as the unit sent; R1 is taken as 6, the next of the PCM90's bank numbers (Appendix C p. 35), unchecked. Preset banks P0-P8 are never dumped (User Guide p. 2-14). Checked on the unit: 0.4, 0.5, 0.9 and 1.0 read as its display shows them.
- Captured from the maker's own PCM91, 22 October 2026, with Control 3.4 Automation on: loading an effect on the front panel sends no Program Change, only F0 06 08 <device ID 7F> 15 <bank> <effect> F7, the PCM90's product number and type 15. Loading P0 3.3 sent 15 00 21 and R0 1.1 sent 15 09 0B: the bank is numbered as Bank Select (CC 32) numbers it, P0-P8 0-8 and R0 9, so R1 is taken as 10, unchecked; the effect is row x 10 + column, as Program Change numbers it. The message carries no MIDI channel. With Automation off the unit sends nothing when an effect is loaded.
- The maker's own PCM91, answering Patchmark's Recognise on 2026-10-11: F0 7E 00 06 02 06 00 00 11 00 01 00 00 00 F7 (Lexicon, family 00 00, member 11 00, version 01 00 00 00). It follows the other Lexicon units' numbering: PCM80 07 00, PCM90 08 00, MPX1 09 00.
- Version request; answered with F0 06 11 <device ID> and the software date, 183 bytes (the maker's unit).
Gaps, and why
- Memory-card banks are not included: the guide's two bank tables disagree on them.
Status
Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.
| Feature | Status |
|---|---|
| Recall | Confirmed: recalled on the maker's own unit, October 2026 |
| Factory names | Confirmed: the factory names shown on the maker's own unit, 1 November 2026 |
| Factory tags | To test |
| Back up | Confirmed: Bank Dumps of R0 and R1 from the maker's own unit, each arriving whole, 22 and 23 October 2026 |
| Restore | Confirmed: a backup sent back to the maker's own unit, October 2026 |
| Names from a backup | Confirmed: a Bank Dump of R0 from the maker's own unit, read as Names… reads it, gives the register names the unit shows, October 2026 |
| Read names from the hardware | Confirmed: R0 and R1 read from the maker's own unit gave the names it shows, empty registers included, 24 October 2026 |
| Rename on hardware | Confirmed: registers in R0 and R1 renamed on the maker's own unit showed the new name, and reading the names gave it back, 23 October 2026 |
| Recognise | Confirmed: the maker's own PCM91 answered, 11 October 2026 |
| Follows its front panel | Confirmed: effects loaded on the maker's own unit in P0, R0 and R1 moved Patchmark's current patch, with Control 3.4 Automation on, 23 October 2026 |
Questions
Does Patchmark edit the PCM91's sounds?
Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. Sound controls you add on the Patch tab it turns from there and the DAW's lanes.
How many PCM91 patches does it know?
550 numbers, in 11 banks, numbered as the unit shows them, row and column. 450 of them carry the maker's names.
Can it back up the PCM91?
Yes, over SysEx, checked on a unit: start a backup in Patchmark, then on the unit: Control 3.8 MIDI Dump: choose Bank R0 or R1 with ADJUST, then press Store.
Does it read the patch names from the PCM91?
Yes, checked on a unit: Library ▸ Read names from hardware… asks the PCM91 for its patches and reads their names.
Has it been checked on a real PCM91?
Yes. Recall: recalled on the maker's own unit, October 2026. Factory names: the factory names shown on the maker's own unit, 1 November 2026. Back up: Bank Dumps of R0 and R1 from the maker's own unit, each arriving whole, 22 and 23 October 2026. Restore: a backup sent back to the maker's own unit, October 2026. Names from a backup: a Bank Dump of R0 from the maker's own unit, read as Names… reads it, gives the register names the unit shows, October 2026. Read names from the hardware: R0 and R1 read from the maker's own unit gave the names it shows, empty registers included, 24 October 2026. Rename on hardware: registers in R0 and R1 renamed on the maker's own unit showed the new name, and reading the names gave it back, 23 October 2026. Recognise: the maker's own PCM91 answered, 11 October 2026. Follows its front panel: effects loaded on the maker's own unit in P0, R0 and R1 moved Patchmark's current patch, with Control 3.4 Automation on, 23 October 2026.
Which DAWs does it work in with the PCM91?
Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.
For beta testers
If you own a Lexicon PCM91, these checks help most (Beta testing):
- Rename a patch in the R0 and R1 banks answering Rename on hardware: does the unit show the new name after a power cycle? Was the backup there?
- Is a memory card fitted?
- Do a preset in P0 and a register in R0 both recall?
- Does Names… on a Bank Dump of R1 give R1's register names?
- Does Read names from hardware on a preset bank (P0–P8) give the names the unit shows?
Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.