Lexicon PCM92
| Question | Answer |
|---|---|
| Does Patchmark work with the PCM92? | Yes, checked on a unit |
| Reads its patch names, from the unit or a backup? | Yes, checked on a unit |
| Backs it up over SysEx? | Yes, checked on a unit |
| Edits its parameters? | No |
Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Lexicon PCM92's patches inside your DAW project (2133 numbers in 42 banks, 1364 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. Patchmark can also back the unit up over SysEx, read its patch names from it and recognise it from a request it answers, as checked on a unit. Recall is confirmed on a real unit: on the maker's own unit as one Device, 1 November 2026.
The whole PCM92 as one Device: System presets on the base channel set up the whole unit, and Machines 1–4 on the next four channels load Mono and Stereo presets into each machine. On the unit (owner's manual pp. 23–24):
- Press Back until the Preset screen shows, then Machine until System View.
- Press the Select knob, turn it to Midi Control, press it.
- MIDI On, Device ID 0.
- Base Channel 0, Machines 1–4 on 1–4: the Select knob picks a line, knob B sets it.
- Press Back twice.
The unit counts channels from 0: its 0–4 are Patchmark's 1–5, so the Device's base channel is the unit's Base Channel plus one. A second PCM92 starts at Base Channel 5.
Bank Select (CC 32) picks a bank and a Program Change the preset: the factory System presets sit in MIDI banks 49–53, the Mono ones in 0–15 and the Stereo ones in 24–39, and your own in the user banks Mono 1–2 (72–73), Stereo 1–2 (74–75) and System 1–2 (76–77). After a System loads, each machine shows what that System put in it.
Readiness: Tested. Tried on our own units.
What Patchmark does with it
- Recall: 2133 patches in 42 banks (Dual Mono, Cascade Stereo, Cascade Mono, Cascade Mono To Stereo, Combined Stereo, System 1, System 2, Mono Hall, Mono Random Hall, Mono Concert Hall, Mono Chamber, Mono Plate, Mono Room, Mono Dual Delay, Mono Random Delay, Mono Chorus, Mono Resonant Chords, Mono Signal Generator, Mono VSO Pitch, Mono Three Voice Pitch, Mono Hall 2, Mono 1, Mono 2, Stereo Hall, Stereo Random Hall, Stereo Concert Hall, Stereo Chamber, Stereo Plate, Stereo Room, Stereo Dual Delay, Stereo Random Delay, Stereo Chorus, Stereo Resonant Chords, Stereo Signal Generator, Stereo VSO Pitch, Dual Mono VSO Pitch, Multi Voice Shift, Stereo Hall 2, Stereo 1, Stereo 2, Single Stereo, Single Mono In Stereo Out), from 1 to 128 in a bank, numbered from 000, as the unit counts (000–127); its factory presets by the unit's own numbers within each front-panel category (Dual Mono Config is Default Configurations 3). Patchmark sends Bank Select LSB (CC 32), then Program Change, on base channel 1 (the System on it, Machines 1–4 on 2–5) to start with.
- Factory names: 1364 patches in 36 of the 42 banks carry the maker's own names.
- Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
- Back up and restore: start a backup in Patchmark, then on the unit: System Menu ▸ MIDI Control ▸ Bank Dump: turn knob B or C to the user bank, then press that knob. (SysEx backup and restore)
- Names from a backup: Names… on a backup reads the patch names out of it.
- Read names from the hardware: Library ▸ Read names from hardware… asks the unit for its patches and reads their names, no backup needed: System 1, System 2, Mono 1, Mono 2, Stereo 1 and Stereo 2, all or one.
- Rename on hardware: after you rename a patch in the System 1, System 2, Mono 1, Mono 2, Stereo 1 and Stereo 2 banks, Patchmark can write the new name into the unit's memory too, and keep a backup first. (Renaming a patch)
- Recognise: the unit answers a request that only reads from it, and Device setup offers this template.
- Follows its front panel: choosing a patch on the unit moves the current patch in the list (When you change the patch on the device).
- Names on the unit: the unit shows patch names; renaming a patch here renames it in Patchmark, and in the System 1, System 2, Mono 1, Mono 2, Stereo 1 and Stereo 2 banks it can rename it on the unit too (above).
Connecting it
- Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and base channel 1 (the System on it, Machines 1–4 on 2–5), the template's default; change it if the unit listens on another.
- The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
- For a backup, or reading names: the unit must send and accept SysEx; its manual says where that is switched on.
- Insert the plugin as an audio effect on any track; the audio passes through untouched.
Sound controls
The Patch tab turns 32 of the PCM92's sound controls, in the Soft row section, and puts any on a DAW lane (Sound controls). Each part's controls go out on that part's own channel.
On the PCM92, MIDI Control: MIDI On, each Machine on a channel of its own. What each soft-row knob moves depends on the Machine's preset: rename the knobs per program.
The Patch tab reaches the soft row, the knobs each preset maps to a CC; the rest of a preset's parameters are edited over SysEx and aren't on the Patch tab (What sound controls can reach).
Values on the Patch tab
Of its 32 controls, 0 show their values as the PCM92's manual gives them (units, names, %), and 32 show the plain number it takes.
Plain numbers: each soft row knob moves whatever parameter the preset's algorithm puts there, so it has no one reading.
Sources
- Lexicon PCM92 Owner's Manual, Part# 5047784-C (2016): pp. 18, 23-25 MIDI Control, a Base Channel for System presets and a channel for each of Machines 1-4 (Setup 2, More Control: base 0, machines 1-4); p. 24 Preset Loading (Controller 32 selects the bank, then a Program Change the preset; the unit remembers the bank per MIDI channel); p. 25 Bank/Preset Map (user banks Mono 1-2, Stereo 1-2 and System 1-2 at MIDI banks 72-77); p. 14 DSP Configurations; p. 53 MIDI Implementation Chart. One template for the whole unit (ADR-047): System on the base channel loads the System banks, Machines 1-4 on the next four channels load the Mono and Stereo banks. The factory System banks' configurations, bank less 48, from Lexicon's PCM96 Preset Reference Guide (the PCM92's factory presets) and the maker's own unit's System dumps, October 2026; Single Stereo, code 0, from a user System saved in it on the maker's own unit; Single Mono In Stereo Out, code 6, likewise, its one machine Stereo: its copy has a Stereo copy's size and layout, and the unit offers it the Stereo presets. The algorithms by the code a Mono or Stereo preset carries at decoded data byte 52, and a System's copy of a machine 8 bytes after its kind, from the maker's own unit's dumps of stored factory presets: Mono Hall 03FE hex (Med Hall), Stereo Chamber 0426 (Medium Chamber), Stereo Hall 042D (Large Hall, and Cathedral 1 of the Hall 2 category), Stereo Plate 042F (Small Plate 1), Stereo Room 0434 (Large Playroom); the other algorithms' codes are not known yet. The factory Mono and Stereo presets' own numbers and front-panel categories and each machine bank's Mono or Stereo kind from the same guide's Standalone Mono (pp. 1-7) and Standalone Stereo (pp. 8-17) lists; two slips in it read the obvious way: Stereo Small RHall 2 (Light) is bank 25 program 19 (printed 35), and Mono Small Rhall 2 is numbers 33-37 (printed 33-35). The factory System presets' own numbers and front-panel categories (Combined Mono Reverbs, Combined Mono Effects, Combined Stereo Reverbs, Combined Stereo Effects, the System part's categories in the front panel's order, owner's manual p. 8) from the same guide's Standalone Combined Presets (pp. 18-19); one slip: Sharp Chamber (bank 50 program 18) is printed as Combined Stereo Reverbs 25 and 27, and is listed as 25 until the unit shows which. Default Configurations (manual pp. 8, 19): program 0 of bank 48 plus the code, names and order as the maker's own unit shows them.
- Lexicon PCM92 Owner's Manual 18-0688-B, pp. 25-26 Continuous Controllers and Soft Row parameter/MIDI CC Map: soft row parameters 1-8 on CC 48-55, on each Machine's channel
- PCM92 Owner's Manual 5047784-C: p. 2 item 8, the OLED display; p. 5, the Preset screen shows the number and name, '0:Large Hall'; p. 10, a preset is named when it is stored
- PCM92 Owner's Manual 5047784-C: p. 18 MIDI Control ▸ Bank Dump (sends one user bank) and Device ID 0-126; p. 24 Bank Dump and Reverse Bank Dump (play the recorded dump back to restore the bank); pp. 26-27 System Exclusive, Lexicon manufacturer ID 06. Product ID 22 hex, which the manual leaves blank: a PCM92's Bank Dump opens F0 06 22 00 01 (Device ID 0; checked on a unit, October 2026). Each stored preset comes as its own Preset Dump (p. 26), empty slots not at all, and the names layout reads it. The manual's Request Preset Dump asks for one stored preset, to rename it; not for Read names, since an empty slot doesn't answer it: Read names asks for the whole bank with Request Preset Bank Dump. Only user banks are sent; factory presets never are (pp. 26-27).
- PCM92 Owner's Manual 5047784-C, p. 26 Command 0, Request Preset Dump: F0 06 <product> <device> 00, the size (2, in four nibbles), then the bank and the preset, answered with that preset's Preset Dump; user banks only, and no reply for an empty slot. The bank and the preset go in two nibbles each, low first, as the Preset Dump carries them; product 22 and device ID 0, as the maker's own unit sent its Bank Dump. It serves the rename of a stored preset only: a read of a bank, slot by slot, would stop at its first empty slot; Read names asks with the bank request instead. Tried on the maker's own unit, 2026-10-31.
- PCM92 Owner's Manual 5047784-C, p. 27 Command 2, Request Preset Bank Dump: F0 06 <product> <device> 02, the size (1, in four nibbles), then the bank in two nibbles, low first, as the Preset Dump carries it. Seen on the maker's own unit, October 2026: F0 06 22 00 02 01 00 00 00 0A 04 F7 (Stereo 1) is answered with one ordinary Preset Dump per stored preset, the first after 165 ms and the next about 125 ms apart; an empty slot sends nothing, and no message ends the bank. So the read ends after a second with nothing, or when preset 127 arrives; a slot that never arrived is empty. User banks only.
- PCM92 Owner's Manual 5047784-C, p. 26 Preset Dump: F0 06 22 <device> 01, then the size in four nibbles, the bank (p. 25: 72-77) in two and the preset in two, low first, then the preset's data in nibbles, low first. The name, 24 characters padded with spaces, is at data byte 54 in Stereo presets (46 in System ones): Bank Dumps of Stereo 1 and System 1 from the maker's own unit, October 2026. Each factory bank's value is its MIDI bank number (p. 25); none is ever sent.
Gaps, and why
- The manual's map counts each kind's second bank 128–255; the list shows those banks as 000–127.
- Lexicon's guide prints Sharp Chamber twice in Combined Stereo Reverbs, as 25 and 27; the list shows it as 25 until the unit shows which.
- What the unit does when a scene recalls a machine its System doesn't use is still to be checked.
- What a user System holds in each machine is known for one- and two-machine Systems read from the unit; three- and four-machine Systems show their machines as unknown until a dump of one is checked.
Status
Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.
| Feature | Status |
|---|---|
| Recall | Confirmed: on the maker's own unit as one Device, 1 November 2026 |
| Factory names | Confirmed: on the maker's own unit, 1 November 2026 |
| Factory tags | To test |
| Back up | Confirmed: on the maker's own unit, 1 November 2026 |
| Restore | Confirmed: on the maker's own unit, 1 November 2026 |
| Names from a backup | Confirmed: on the maker's own unit, 1 November 2026 |
| Read names from the hardware | Confirmed: on the maker's own unit, 1 November 2026 |
| Rename on hardware | Confirmed: on the maker's own unit, 1 November 2026 |
| Recognise | Confirmed: on the maker's own unit, 1 November 2026 |
| Follows its front panel | Confirmed: on the maker's own unit, 1 November 2026 |
Questions
Does Patchmark edit the PCM92's sounds?
Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. It turns the PCM92's sound controls from the Patch tab and the DAW's lanes, over MIDI.
How many PCM92 patches does it know?
2133 numbers, in 42 banks, numbered from 000, as the unit counts (000–127); its factory presets by the unit's own numbers within each front-panel category (Dual Mono Config is Default Configurations 3). 1364 of them carry the maker's names.
Can it back up the PCM92?
Yes, over SysEx, checked on a unit: start a backup in Patchmark, then on the unit: System Menu ▸ MIDI Control ▸ Bank Dump: turn knob B or C to the user bank, then press that knob.
Does it read the patch names from the PCM92?
Yes, checked on a unit: Library ▸ Read names from hardware… asks the PCM92 for its patches and reads their names.
Has it been checked on a real PCM92?
Yes. Recall: on the maker's own unit as one Device, 1 November 2026. Factory names: on the maker's own unit, 1 November 2026. Back up: on the maker's own unit, 1 November 2026. Restore: on the maker's own unit, 1 November 2026. Names from a backup: on the maker's own unit, 1 November 2026. Read names from the hardware: on the maker's own unit, 1 November 2026. Rename on hardware: on the maker's own unit, 1 November 2026. Recognise: on the maker's own unit, 1 November 2026. Follows its front panel: on the maker's own unit, 1 November 2026.
Which DAWs does it work in with the PCM92?
Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.
For beta testers
If you own a Lexicon PCM92, these checks help most (Beta testing):
- Rename a patch in the System 1, System 2, Mono 1, Mono 2, Stereo 1 and Stereo 2 banks answering Rename on hardware: does the unit show the new name after a power cycle? Was the backup there?
- Which firmware?
- Do factory presets in the Dual Mono bank recall the System the list names?
- With a System loaded, does a Mono preset recalled into Machine 1 load into the unit's first machine?
- Do presets in the System 1, Mono 1 and Stereo 1 user banks recall?
- Does the first preset of Stereo 2 show as 128?
Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.
This manual is for version 0.9.7.