Patchmark‹ All plug-ins
Manual contents
For version 0.9.7 · beta · Change

You're reading the manual for Patchmark 0.9.7. Go to this page for 0.9.9

Devices

Lexicon MPX200

Question Answer
Does Patchmark work with the MPX200? Documented, untested
Reads its patch names, from the unit or a backup? No
Backs it up over SysEx? Documented, untested
Edits its parameters? No

Patchmark is a free MIDI librarian plugin (Audio Unit and VST3) for macOS that lists the Lexicon MPX200's patches inside your DAW project (304 numbers in 4 banks, 240 of them with the maker's names) and recalls one by sending Bank Select LSB (CC 32), then Program Change. Patchmark can also back the unit up over SysEx, following the maker's documentation; this is not yet checked on a unit. Recall follows the maker's documentation; nobody has checked it on a unit yet.

The unit numbers its 240 presets 1–240 and its 64 User programs U1–U64; the template reaches each hundred with Bank Select (CC 32) and the rest with a Program Change, and numbers them as the unit does. The unit shows numbers only, so Patchmark supplies the factory names, and it backs up the User programs from the unit's own MIDI dump.

Readiness: Testing required. Checked line by line against the manufacturer's manuals, not yet tried on a real unit.

The Lexicon MPX200 template isn't built into Patchmark: in Device setup, choose Templates ▾ ▸ Get more from the website…, then Install beside it.

What Patchmark does with it

  • Recall: 304 patches in 4 banks (001-099, 100-199, 200-240, User (301-364 = U1-U64)), from 41 to 100 in a bank, numbered by the hundred, bank and patch together, as the unit shows them (000–399). Patchmark sends Bank Select LSB (CC 32), then Program Change, on MIDI channel 1 to start with.
  • Factory names: 240 patches in 001-099, 100-199, 200-240 carry the maker's own names.
  • Factory tags: each factory patch is tagged (Hall, Bass, Vocal…), so the Tags filter finds them (Tags).
  • Back up and restore: start a backup in Patchmark, then on the unit: System Mode (hold Bypass 2 seconds), press Bypass until 15 Dump User Bank, turn Adjust to 1 and press Store; then 17, 33 and 49 the same way, each within 30 seconds of the last. (SysEx backup and restore)
  • Names on the unit: the unit shows numbers only, so the names you see are Patchmark's.

Connecting it

  • Connect the unit's MIDI In to your interface's MIDI Out (or its USB, where it has one), then pick that port under Device setup ▸ Output, and MIDI channel 1, the template's default; change it if the unit listens on another.
  • The unit must receive Program Change and Bank Select LSB (CC 32); where the maker's manual says how to set that, it is cited in Sources below.
  • For a backup, or reading names: keep System Mode's MIDI OUT/THRU (13) on Out, the factory setting, so the dump leaves by the MIDI OUT/THRU jack.
  • Insert the plugin as an audio effect on any track; the audio passes through untouched.

Sound controls

No list comes with the MPX200: add its controls on the Patch tab with Add control… (Sound controls).

On the MPX200, Learn mode gives a front-panel knob or button its CC. Add the same CCs here with Add control, or Learn them.

The Patch tab reaches only what the MPX200 maps to a CC or NRPN, not the parameters it edits over SysEx alone (What sound controls can reach).

Sources

  • Lexicon MPX 200 User Guide 070-14738 Rev 2 (2002), the printed pages (manuals repo): p. 2-2 and p. 4-2, 240 presets numbered 1-240 and 64 User programs U1-U64; p. 3-3, MIDI Program Change On by default; p. 5-2, one MIDI channel (default 1), CC 32 bank 0 = programs 1-99, 1 = 100-199, 2 = 200-240, 3 = User; p. 5-3 worked examples and the MIDI chart p. 5-8: program = 100 x bank + Program Change, User Un = Program Change n, and a Program Change to a missing program or an empty User location does nothing. The patches are numbered as the unit numbers its presets, so bank 0's 000 recalls nothing, bank 2 stops at 240, and the User bank's 301-364 are U1-U64: each bank leaves out the places it has no program at (000, 241-299, 300 and 365-399), 99, 100, 41 and 64 programs. Factory names from chapter 4's tables, pp. 4-3 to 4-30, every one as printed; the Mono Split and Dual Mono tables (pp. 4-27 to 4-29) print a program's two effects in two columns, so 190-224 are joined with '+' and 225-240 with ' | ', as Lexicon's MPX 500 Program Change chart names the same programs. The unit's display shows numbers only (p. 2-2). The User bank is yours, so it has no names here. Tags: each program by its category (a detune is Chorus, tremolo and rotary Modulation, a compressor Dynamics), plus Vocal, Drums and Guitar by name and Delay for a slap; a Dual or Mono Split program by the effects its name abbreviates (Fl, Chor, a pitch interval, a delay pattern), a Small, MidSize or Room as Room and a Large as Hall; Special FX one by one, a reverb whose name gives no space as Hall, a name that names no effect as Ambience, and Stereo Stage as Utility. Backup: System Mode's MIDI Dumps (hold Bypass 2 seconds; 15 Dump User Bank, in groups of 16 chosen with Adjust: 1, 17, 33, 49; 16 the current program; 17 the System settings and Learned patches; each sent when Store is pressed, pp. 3-7 and 5-6) go out of MIDI OUT/THRU set to Out (System 13, Out by default). The MIDI chart (pp. 5-7 to 5-8) sends and recognises Lexicon SysEx (product ID 21 decimal, device ID the MIDI channel), and sends no Program Change and no universal SysEx: the unit can't say which program was chosen on it or who it is. Lexicon's MPX Series MIDI Implementation, User Guide Addendum 070-14979 Rev 1 (09/02), pp. 4-6 and the MPX 200 tables pp. 20-31, documents parameter Query and Data messages only (product ID 15 hex): no program dump format, no dump request and no name position, so a dump is kept as received; its dump events aren't explained, and two of them clear the unit's memory, so Patchmark never sends them. Unconfirmed: no unit has been checked.
  • MPX 200 User Guide p. 2-2 and p. 2-9: a three-digit display shows the program number, with U for a User program; names aren't shown
  • MPX 200 User Guide pp. 3-7 and 5-6: Dump User Bank sends the User programs in groups of 16 (1, 17, 33, 49) when Store is pressed, and a group sent back returns to its own User locations; the MIDI chart pp. 5-7 to 5-8: Lexicon SysEx sent and recognised. Their format isn't documented: a dump is kept as received and sent back as it came.

Gaps, and why

  • Names from a backup: the unit keeps no names: its display shows a program's number only.
  • Read names from the hardware: the unit keeps no names: its display shows a program's number only.
  • Recognise: its MIDI chart says it sends no universal SysEx, so it can't answer being asked who it is.
  • Follows its front panel: its MIDI chart says it sends no Program Change, so choosing a program on it can't be followed.
  • The patches are numbered as the unit numbers its programs, so a few numbers recall nothing: 000, 241–299, 300 and 365–399. The User bank's 301–364 are the unit's U1–U64, and an empty User location ignores the recall.
  • A backup is kept as received: Lexicon doesn't document the dump's format. Sending it back is how the guide expects a sequencer to restore one; each group of 16 returns to its own User locations.
  • The printed Mono Split and Dual Mono lists (190–240) set a program's two effects in two columns; the template joins them with + and |, as Lexicon's MPX 500 chart names the same programs.

Status

Confirmed means checked on a real unit; to test means it follows the sources but nobody has checked it on a unit yet.

Feature Status
Recall To test
Factory names To test
Factory tags To test
Back up To test
Restore To test

Questions

Does Patchmark edit the MPX200's sounds?

Not the patches themselves: it lists them by name, recalls them and keeps the names, and the sounds stay on the unit. Sound controls you add on the Patch tab it turns from there and the DAW's lanes.

How many MPX200 patches does it know?

304 numbers, in 4 banks (001-099, 100-199, 200-240, User (301-364 = U1-U64)), numbered by the hundred, bank and patch together, as the unit shows them (000–399). 240 of them carry the maker's names.

Can it back up the MPX200?

Not yet checked on a unit. Following the maker's documentation, it backs the unit up over SysEx: start a backup in Patchmark, then on the unit: System Mode (hold Bypass 2 seconds), press Bypass until 15 Dump User Bank, turn Adjust to 1 and press Store; then 17, 33 and 49 the same way, each within 30 seconds of the last.

Does it read the patch names from the MPX200?

Not yet: the unit keeps no names: its display shows a program's number only.

Has it been checked on a real MPX200?

Not yet: it follows the maker's documentation cited in Sources, and a beta tester with one can confirm it (Beta testing).

Which DAWs does it work in with the MPX200?

Any macOS DAW that loads Audio Unit (AU) or VST3 effects; tested in Logic Pro and Ableton Live.

For beta testers

If you own a Lexicon MPX200, these checks help most (Beta testing):

  • Do patches 001, 157 and 240 recall the programs of those numbers?
  • Does patch 301 recall U1?
  • Start a backup, then on the unit: System Mode (hold Bypass 2 seconds), Bypass to 15 Dump User Bank, Adjust to 1, Store; then 17, 33 and 49. Is one backup saved with all four groups? After changing a User program, does restoring it bring the program back?
  • Send us a Dump User Bank backup, with the names of your first few User programs as the unit shows them: it shows where a backup keeps the names. (How and where)

Eventide, Korg, Lexicon, Nord, Novation, Roland, Sequential, TC Electronic, Yamaha and other product and company names are trademarks of their respective owners. They are used only to identify the devices Patchmark works with. Patchmark is not affiliated with, sponsored or endorsed by them.

This manual is for version 0.9.7.